PLSED309039EN PM1000 Series Power Meters
08/2010 Chapter 6 Data Communication
© 2010 Schneider Electric. All rights reserved.
57
Forward Integrated Block
Function Code: 03H Read
Number of registers: 20
No scaling required
Read as block only
Table 6-9: Forward integrated block
Parameter
Description
Address
Type
PM1200
FwdVAh
Forward apparent energy
3121
Float
FwdWh
Forward active energy
3123
Float
FwdVARh
Forward reactive inductive
energy
3125
Float
Reserved
Reserved
3127
Float
Reserved
Reserved
3129
Float
FwdVARh
Forward reactive capacitive
energy
3131
Float
Reserved
Reserved
3133
Float
Reserved
Reserved
3135
Float
Reserved
Reserved
3137
Long
FwdRunsecs
Forward run seconds
3139
Long
Reverse Integrated Block:
Function Code: 03H Read
Number of registers: 20
No scaling required
Read as block only
Table 6-10: Reverse integrated block
Parameter
Description
Address
Type
PM1200
RevVAh
Reverse apparent energy
3151
Float
RevWh
Reverse active energy
3153
Float
RevVARh
Reverse reactive inductive energy
3155
Float
Reserved
Reserved
3157
Float
Reserved
Reserved
3159
Float
RevVARh
Reverse reactive capacitive energy
3161
Float
Reserved
Reserved
3163
Float
Reserved
Reserved
3165
Float
Reserved
Reserved
3167
Long
RevRunsecs
Reverse run seconds
3169
Long