Schneider Electric Multi-Loader Especificações

Consulte online ou descarregue Especificações para Medição, teste e controlo Schneider Electric Multi-Loader. Schneider Electric Multi-Loader Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Altivar
®
12
variable speed drives
For 3-phase motors from 0.18 to 4 kW
Catalog
2010
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1

Altivar® 12 variable speed drivesFor 3-phase motors from 0.18 to 4 kW Catalog2010Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisc

Página 2

123456789108Altivar® 12 variable speed drivesIntroductionIntroductionThe Altivar® 12 drive is a frequency inverter for three-phase 200 to 240 V asynch

Página 3 - Contents

123456789109Introduction (continued)Altivar® 12 variable speed drivesAn optimum solutionThe Altivar® 12 range of variable speed drives extends across

Página 4 - High-performance

1234567891010SpecicationsAltivar® 12 variable speed drivesIntroduction:page 8References:page 14Dimensions:page 18Connections:page 22Functions:page 26

Página 5 - Small Economical

1234567891011Specications (continued)Altivar® 12 variable speed drivesDrive specicationsOutput frequency range Hz 0.5 to 400Congurable switching fr

Página 6 - Easy to

1234567891012Electrical specications (control)Available internal supplies Protected against short-circuits and overloads:One 5 V ⎓ supply (± 5%) for

Página 7 - Versatile

1234567891013Specications (continued)Altivar® 12 variable speed drivesCommunication port specications Protocol Modbus®Structure Connector 1 RJ45 con

Página 8 - Selection guide

1234567891014Drives with heatsinkMotor Line supply Altivar 12Power indicated on rating plate (1)Max. line current (3)Apparent powerMax. prospec-tive l

Página 9 - ATV12 ATV312 ATV21

1234567891015References (continued)Altivar® 12 variable speed drivesAccessories,congurationtoolsAccessoriesDescription For drives Reference Weightk

Página 10 - Introduction

1234567891016References (continued)Altivar® 12 variable speed drivesCongurationtools,remotedisplayterminals,brakingunitandresistors,additiona

Página 11 - (continued)

1234567891017References (continued)Altivar® 12 variable speed drivesMotor chokes, Modbus® serial link,documentation, replacement partsMotor chokesDesc

Página 12 - Specications

2 1Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-920

Página 13

1234567891018DimensionsDrives with heatsinks (1)ATV12H018F1, H037F1, ATV12H018M2 to H075M2, ATV12H018M3 to H075M3Drive with EMC conformity kit VW3A952

Página 14

1234567891019Introduction:page 8Specications:page 10References:page 14Connections:page 22Functions:page 26Dimensions (continued), mounting recommenda

Página 15 - Specications (continued)

1234567891020Dimensions (continued)Altivar® 12 variable speed drivesAccessories, remote display terminal, brakingunitandresistors,motorchokes,EMC

Página 16 - References

1234567891021Mounting recommendationsInstall the unit vertically, at ± 10°.Avoid placing it close to heating elements.Leavesufcientfreespacetoen

Página 17

1234567891022ConnectionsAltivar® 12 variable speed drivesDrivesRecommended connectionsTypical connection for ATV12ppppF1, ATV12ppppM2 Typical connecti

Página 18 - References (continued)

1234567891023Connections (continued), installation recommendationsAltivar® 12 variable speed drivesBraking unit and resistors, motor chokes,additional

Página 19

1234567891024ApplicationsThe proposed combinations can:b Protect people and equipment (when a short-circuit occurs)b Maintain protection upstream o

Página 20 - Drives with heatsinks

1234567891025Combinations for customer assembly (continued)Altivar® 12 variable speed drivesMotor starters: Three-phase supply voltage200 to 240 VMot

Página 21 - Drives on a base plate

1234567891026Summary of functionsFactory-set drive congurationIntroduction page 27Human/Machine Interface (HMI)Description page 27Application functio

Página 22 - Dimensions (continued)

1234567891027Functions (continued)Altivar® 12 variable speed drivesFactory-set drive congurationThe Altivar®12driveisconguredtoallowimmediate

Página 23 - Mounting

2 1ContentsAltivar® 12 variable speed drivesOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Selection

Página 24 - Connections

1234567891028Altivar® 12 variable speed drivesFunctions (continued)Application functionsOperating speed rangeDeterminesthetwofrequencylimitswhich

Página 25 - Connections (continued)

1234567891029Functions (continued)Altivar® 12 variable speed drivesPID regulatorUsedforsimplecontrolofaowrateorapressurewithasensorwhic

Página 26 - Combinations for

1234567891030Functions (continued)Altivar® 12 variable speed drivesRamp time switchingThis function is used to switch two acceleration and deceleratio

Página 27

1234567891031Functions (continued)Altivar® 12 variable speed drivesLimiting low speed operating timeThe motor is stopped automatically after a period

Página 28 - Functions

1234567891032Functions (continued)Altivar® 12 variable speed drives2nd current limitA 2ndcurrentlimitcanbeconguredbetween0.25and1.5timesth

Página 29 - Functions (continued)

1234567891033Functions (continued)Altivar® 12 variable speed drivesFault relay, unlockingThe fault relay is energized when the drive is powered up and

Página 30

1234567891034Functions (continued)Altivar® 12 variable speed drivesUnderload detectionThis function stops the motor when it is underloaded. The functi

Página 31

1234567891035Functions (continued)Altivar® 12 variable speed drivesPump-specic application functionsThemainobjectivehereistocontrolacomplete

Página 32

1234567891036Functions (continued)Altivar® 12 variable speed drivesUnderload detectionSee page 34.Overload detectionSee page 34.Sleep/Wake-upAllowsth

Página 33

1234567891037Functions (continued)Altivar® 12 variable speed drivesQuick startThe quick start function aims to overcome the problems associated with t

Página 34

123456789102SmallIntuitiveMake the most of your energySMReliableHigh-performanceThe Altivar® 12 variable speed drive gives you greater reliability and

Página 35

ART. 9 60297The information and dimensions in this catalog are provided for the convenience of our customers. While this information is believed to

Página 36

123456789103The Altivar 12 is well-suited for use in applications involving simple industrial machines or certain consumer machines. Its compact size,

Página 37

123456789104Easy to integrate – the Altivar 12 is an extremely efficient drive. Its design and rugged components make it both reliable and durable.No c

Página 38

123456789105The Altivar® 12 variable speed drive is immediately operational. It’s configured using its notched wheel or from the SoMove software worksh

Página 39 - Variable pump frequency

123456789106Pumps and fans(industrial)Complex machines 0.37 to 800 0.37 to 630– –0.37 to 5.5 0.37 to 5.5– –0.75 to 90 0.37 to 750.75 t

Página 40

123456789107Pumps and fans(industrial)Complex machines 0.37 to 800 0.37 to 630– –0.37 to 5.5 0.37 to 5.5– –0.75 to 90 0.37 to 750.75 t

Comentários a estes Manuais

Sem comentários