Schneider Electric ALTIVAR 58 TRX Guia de Instalação Página 40

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 126
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 39
© 1998–2003 Schneider Electric All Rights Reserved
Chapter 2—Menus VVDED397047USR6/03
2—Adjust Menu 06/2003
40
BrReleasTime -s
[4]
brt Brake release time 0 to 5 s 0 s
BrEngageLev- Hz
[4]
bEn Brake engage frequency 0 to LSP 0 Hz
BrEngageTime -s
[4]
bEt Brake engage time 0 to 5 s 0 s
PI Prop. Gain rPG Proportional gain for PI regulator 0.01 to 100 1
PI Int. Gain-/s rIG Integral gain for PI regulator
0.01 to 100
/s
1 /s
PI Coeff. FbS
Feedback scaling factor for PI
regulator
1.0 to 100.0 1.0
PI Inversion PIC
Inverts the PI feedback signal
No: Normal Yes: Inverted
Yes - No No
PI Filter -s PSP
Used to adjust the low-pass filter
time constant on the PI
feedback signal.
0 to 10 s 0 s
PI Preset 2 - % PI2
Second preset PI reference.
Available after a logic input has
been assigned to PR4: PI4
Preset
0-100% 30%
PI Preset 3- % PI3
Third preset PI reference.
Available after a logic input has
been assigned to PR4: PI4
Preset
0-100% 60%
ATV th. fault dtd
Drive thermal fault threshold
above which the logic output
goes to state 1, after a logic
input has been assigned to
tAd:ATV th. alarm.
0-118% 105%
Freq. Detect-Hz Ftd
Motor frequency threshold
above which the logic output
goes to state 1.
LSP to HSP
50/60
Hz
[1]
Freq.Lev.2- Hz F2d
Same function as Ftd for a
second frequency value
LSP to HSP
50/60
Hz
[1]
Table 10: 2—Additional Adjustment Parameters After I/O
Reassignment (continued)
Parameter Code Description
Adjustment
Range
Factory
Setting
[1]
Depending on the position of the 50/60 Hz switch.
[2]
100% corresponds to the nominal torque of a motor with horsepower size equal to that
of the drive controller at its constant torque rating.
[3]
I
n
= drive controller constant torque output current rating shown on the drive controller
nameplate.
[4]
This parameter is not available on 125–500 hp drive controllers.
These parameters are available only with the I/O extension card installed.