94
© 19982001 Schneider Electric All Rights Reserved
OPF
MOTOR PHASE LOSS
1. Loss of a phase on the output of the
drive controller.
2. Drive controller oversized for motor.
1. Check the wiring to the motor (Procedure 3 on
page 90).
2. Disable OPL and provide external overload
protection.
OSF
OVERVOLTAGE
Supply too high. See Table 26. 1. Check input line voltage (Procedure 2 on page 89).
2. Reset the drive controller.
OtF
MOTOR OVERHEATING
Motor temperature too high. 1. Check the motor ventilation, ambient temperature,
and motor load.
2. Check the type of thermal sensors used.
PHF
INPUT PHASE LOSS
1. Input phase loss.
2. Power fuses blown.
3. Input line failure (t > 1s).
1. Check input line voltage (Procedure 2 on page 89).
2. Check fuses and circuit breaker (Procedure 3 on
page 90).
3. Reset.
rnF
RAMP NOT FOLLOWED
1. Ramp not followed.
2. Speed opposite from reference.
1. Check the adjustment and wiring of the speed
feedback.
2. Check the adjustments against the load.
3. Check the sizing of the motor/drive controller
combination. Dynamic Braking may be necessary.
SCF
MOT SHORT CKT
Short circuit or grounding on drive
controller output.
1. Remove all power. With drive controller
disconnected, check connecting cables and motor
insulation.
2. Check the drive controller transistors.
SLF
LOSS OF RS485
Bad connection between the drive
controller and the programming keypad
display.
Check the connection between the drive controller
and the programming keypad display.
SOF
OVERSPEED
1. Instability.
2. Overhauling load.
1. Check parameter adjustments.
2. Add Dynamic Braking.
3. Verify the sizing of the motor, drive controller, and
load.
SPF
SPEED FEEDBACK
FAULT
Loss of speed feedback. Check the wiring of the sensor.
tSF
THERMAL SENSOR
FAULT
Bad connection between the motor
thermal sensors and the drive controller.
1. Check the connection between the thermal sensors
and the drive controller.
2. Check the thermal sensors.
USF
UNDERVOLTAGE
1. Supply is too low.
2. Temporary voltage drop (t
200 ms).
Check input line voltage (Procedure 2 on page 89).
Table 26: Overvoltage/Overbraking Trip and Reset Points
Overvoltage Trip
Point
Overbraking Trip
Point
Reset Point
ATV58••••M2 395 Vdc 415 Vdc 385 Vdc
ATV58••••N4 800 Vdc 840 Vdc 785 Vdc
Table 25: Fault Codes and Messages (Continued)
Fault/Message Probable Causes Corrective Actions
Vista de página 93