4 For up to date pricing visit RS Online today!SCHNEIDER ELECTRIC AUTOMATION SOLUTIONS
TESYS MOTOR CIRCUIT BREAKERS
Page 1007
Stock No. Description Man Part No.
395-0194 24-32A FLC 10kA GV2ME32
395-0217 13-18A FLC 15kA GV2ME20
395-0245 4-6.3A FLC 100kA GV2ME10
395-0289 1-1.6A FLC 100kA GV2ME06
GV2ME THERMAL MAGNETIC
MOTOR CIRCUIT BREAKERS
•Local control with stop start rocker levers
•Short circuit & thermal overload protection
•Screw termination
Page 1008
Stock No. Description Man Part No.
400-1984 Connection from top GV1G09
608-8208 Fitted with GV1L3 GV2G05
610-1070 Protective end cover GV1G10
GV2 POWER TERMINAL
BLOCKS
•For use with GV2 motor circuit breakers
Page 1008
Stock No. Description Man Part No.
608-8551 1-1.6A FLC 100kA GV2RT06
608-8567 2.5-4A FLC 100kA GV2RT08
608-8573 4-6.3A FLC 100kA GV2RT10
608-8595 9-14A FLC 15kA GV2RT16
GV2RT THERMAL MAGNETIC
MOTOR CIRCUIT BREAKERS
•For motors with high peak starting current
•For primaries of 3 phase transformers
•Local control by toggle switch
Page 1008
Stock No. Description Man Part No.
395-0122 LHS mount 1NO+1NC GVAN11
395-0144 Front mount 1NO+1NC GVAE11
395-0627 Front mount 1NO or 1NC GVAE1
400-1401 LHS mount C/O GVAM11
GV2/3 AUXILIARY
CONTACTS
•For use with GV2/3 motor circuit breakers
•Operates when starter is switched "ON" or "OFF"
Page 1007
Stock No. Description Man Part No.
305-2199 4-6.3A FLC 100kA GV2P10
305-2212 9-14A FLC 100kA GV2P16
608-8517 0.25-0.4A FLC 100kA GV2P04
608-8545 24-32A FLC 35kA GV2P32
GV2P THERMAL
MAGNETIC MOTOR
CIRCUIT BREAKERS
•Local control with rotary switch
•Visible fault indication
•Suitable for use with
extendable handle
Page 1008
Stock No. Description Man Part No.
400-1990 2 way 45mm pitch GV2G245
400-2000 4 way 45mm pitch GV2G445
608-8236 3 way 54mm pitch GV2G354
608-8258 5 way 54mm pitch GV2G554
GV2 POWER
TERMINAL BUSBARS
•For incoming power connections to
GV2 motor circuit breakers
•45mm pitch
Stock No. Description Man Part No.
608-8810 132-220A FLC 35kA GV7RE220
608-8848 60-100A FLC 70kA GV7RS100
608-8860 25-40A FLC 70kA GV7RS40
608-8876 48-80A FLC 70kA GV7RS80
GV7R THERMAL MAGNETIC
MOTOR CIRCUIT BREAKERS
•Screw fixing or DIN rail mounting
•Toggle lever control
•Connection by screw clamp
Stock No. Description Man Part No.
608-8775 Terminal shields GV7AC01
608-8781 Auxiliary contacts GV7AE11
GV7 AUXILIARY
CONTACTS
•Allows remote indication of the
starter contact state
•Insulation voltage 690A
•Thermal current 6A
Stock No. Description Man Part No.
272-886 9-13A FLC 180A GV3P13
272-909 17-25A FLC 325A GV3P25
272-921 30-40A FLC 520A GV3P40
272-937 48-65A FLC 845A GV3P65
GV3 THERMAL MAGNETIC
MOTOR CIRCUIT BREAKERS
•Everlink terminals for long lasting connections
•IP65 rated enclosure
•3 position padlockable
rotary knob