Schneider Electric 170AMM11030 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Redes Schneider Electric 170AMM11030. Schneider Electric 170AMM11030 User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 704
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
31001697.16
www.schneider-electric.com
Modicon Mo mentum I/O Base
31001697 10/2013
Modicon Momentum I/O
Base
User Guide
10/2013
Vista de página 0
1 2 3 4 5 6 ... 703 704

Resumo do Conteúdo

Página 1 - Modicon Momentum I/O

31001697.16www.schneider-electric.comModicon Mo mentum I/O Base31001697 10/2013Modicon Momentum I/O BaseUser Guide10/2013

Página 2 - 2 31001697 10/2013

10 31001697 10/2013Chapter 28 170 ADO 530 50 120 VAC - 8 Point Discrete Output @ 2A Module Base . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 3 - Table of Contents

170 AAI 030 0010031001697 10/20131 ... 5 VThe following illustration shows the analog/digital relation for the input measuring range 1 ... 5 V. 4 ...

Página 4 - 4 31001697 10/2013

31001697 10/2013 101Modicon M omentum I/O Base170 AAI 140 0031001697 10/2013170 AAI 14 0 00 Analog 16 Chan nel Single-Ended I nput Modu le BaseChapter

Página 5 - 31001697 10/2013 5

170 AAI 140 0010231001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AAI 140 00 I/O base

Página 6 - 6 31001697 10/2013

170 AAI 140 0031001697 10/2013 103LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 7 - 31001697 10/2013 7

170 AAI 140 0010431001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AAI 140 00 I/O base. General SpecificationsIso

Página 8 - 8 31001697 10/2013

170 AAI 140 0031001697 10/2013 105Physical DimensionsAnalog InputsRange Specific DataNOTE: *Not to be confused with Protective Earth. PE is used here

Página 9 - 31001697 10/2013 9

170 AAI 140 0010631001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 10 - 10 31001697 10/2013

170 AAI 140 0031001697 10/2013 107Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions. Required Terminal ConnectorT

Página 11 - 31001697 10/2013 11

170 AAI 140 0010831001697 10/2013Signal ProtectionTo protect the signal from external noise induced in serial or common mode, we recommend the followi

Página 12 - 12 31001697 10/2013

170 AAI 140 0031001697 10/2013 109Wiring DiagramsOverviewThis section contains a diagram to assist you in wiring this I/O base for voltage input and c

Página 13 - 31001697 10/2013 13

31001697 10/2013 11Chapter 32 170 ADO 830 30 6 Pt. Relay Out Module Base . . . . . . . 515Front Panel Components. . . . . . . . . . . . . . . . . . .

Página 14 - 14 31001697 10/2013

170 AAI 140 0011031001697 10/2013I/O MappingOverviewThe 170 AAI 140 00 TSX Momentum I/O base supports 16 analog inputs. This section contains informat

Página 15 - Safety Information

170 AAI 140 0031001697 10/2013 111Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be comm

Página 16 - 16 31001697 10/2013

170 AAI 140 0011231001697 10/2013IllustrationParameters are set by entering a four-bit code in output words 1 ... 4, as follows: Codes for Analog Inpu

Página 17 - About the Book

170 AAI 140 0031001697 10/2013 113Analog InputsOverviewThis section describes how to interpret the value of the analog input channels.KeyThis section

Página 18 - Related Documents

170 AAI 140 0011431001697 10/2013Analog Input ValuesMapping of analog input values is shown below.Broken Wire IndicationBroken wire detection is possi

Página 19 - Using Momentum I/O Bases

170 AAI 140 0031001697 10/2013 115Input Measuring RangesOverviewThis section contains illustrations explaining the analog/digital relation for the thr

Página 20

170 AAI 140 0011631001697 10/2013+/- 5 VThe following illustration shows the analog/digital relation at +/- 5 V:4 ... 20 mAThe following illustration

Página 21 - Chapter 1

31001697 10/2013 117Modicon M omentum I/O Base170 AAI 520 4031001697 10/2013170 AAI 520 40 Analog 4 Channel RTD, Therm. and mV Input Module BaseChapte

Página 22 - Basic Features of I/O Bases

170 AAI 520 4011831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AAI 520 40 I/O base

Página 23 - 31001697 10/2013 23

170 AAI 520 4031001697 10/2013 119LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 24 - Types of I/O Bases

12 31001697 10/2013Chapter 35 170AMM11030 Analog 2 Ch. In / 2 Ch. Out Module Base with 16 Discrete Inputs and 8 Discrete Output Points . . . . . . .

Página 25 - Discrete

170 AAI 520 4012031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AAI 520 40 I/O base.General SpecificationsIsol

Página 26 - Specials

170 AAI 520 4031001697 10/2013 121FusesEMCPhysical DimensionsAnalog Inputs mV RangeInternal (not user-replaceable) 2 A slow-blowExternal (recommended)

Página 27 - Chapter 2

170 AAI 520 4012231001697 10/2013RTD Ranges for Pt100/Pt1000Errors for Pt100/Pt1000Maximum error at 25 degrees C in degrees C (1)Range Pt100 (IEC751)

Página 28 - Selecting Other Components

170 AAI 520 4031001697 10/2013 123(1) The values shown in brackets correspond to the maximum errors for temperatures in the range 0 ... 60 degrees C o

Página 29 - Terminal Connectors

170 AAI 520 4012431001697 10/2013(1) The values shown in brackets correspond to the maximum errors for temperatures in the range 0 ... 60 degrees C or

Página 30 - Communication Adapters

170 AAI 520 4031001697 10/2013 125Thermocouple Errors in Degrees CMaximum error at 25 degrees C in degrees C (1) (1) The values shown in brackets corr

Página 31 - Processor Adapters

170 AAI 520 4012631001697 10/2013Thermocouple Ranges in Degrees FInput span and resolution in degrees F Thermocouple TypeB E J K N R S TInput span 32

Página 32 - For More Information

170 AAI 520 4031001697 10/2013 127Thermocouple Errors in Degrees FMaximum error at 77 degrees F in degrees F (1)Temperature Thermocouple TypeB E J K

Página 33 - Option Adapters

170 AAI 520 4012831001697 10/2013(1) The values shown in brackets correspond to the maximum errors for temperatures in the range 0...60 degrees C or 3

Página 34

170 AAI 520 4031001697 10/2013 129Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 35 - Ordering Information

31001697 10/2013 13Analog Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 651Discrete I/O Points and IEC

Página 36

170 AAI 520 4013031001697 10/2013Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions. Terminal ConnectorTo connect

Página 37 - 31001697 10/2013 37

170 AAI 520 4031001697 10/2013 131Signal ProtectionTo protect the signal from external noise induced in serial or common mode, we recommend the follow

Página 38

170 AAI 520 4013231001697 10/2013Wiring DiagramsOverviewThis section contains an illustration to assist you in wiring the following types of devices:

Página 39 - Chapter 3

170 AAI 520 4031001697 10/2013 133I/O MappingOverviewThe 170 AAI 520 40 TSX Momentum I/O base supports 4 analog inputs. This section contains informat

Página 40 - Assembly

170 AAI 520 4013431001697 10/2013Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be commi

Página 41 - Procedure

170 AAI 520 4031001697 10/2013 135ParametersFor each input channel, you may set the following parameters:NOTE: The 0000 reserved value is more a contr

Página 42

170 AAI 520 4013631001697 10/2013RTD Parameter CodesUse the following codes to set your choice of parameters:Thermocouple N 1/10 degrees C disabled 12

Página 43

170 AAI 520 4031001697 10/2013 137IEC PT1000 RTD 2- or 4-wire 1/10 degrees C disabled 0221 enabled 0321 1/10 degrees F disabled 02A1 enabled 03A1 3-wi

Página 44

170 AAI 520 4013831001697 10/2013Low Voltage Parameter CodesUse the following codes to set your choice of parameters:DIN Ni1000 RTD 2- or 4-wire 1/10

Página 45 - 31001697 10/2013 45

170 AAI 520 4031001697 10/2013 139Analog InputsOverviewThis section describes how to interpret the value of the analog input channels.KeyThis section

Página 46

14 31001697 10/2013

Página 47

170 AAI 520 4014031001697 10/2013Broken Wire Indication A broken wire indication has the following values:+/-25mv+/-100mvNi100 Ni1000 Pt100 Pt1000 T S

Página 48

170 AAI 520 4031001697 10/2013 141RTD, Thermocouple and mV Input Measuring RangesOverviewThis section contains illustrations explaining the analog/dig

Página 49 - 31001697 10/2013 49

170 AAI 520 4014231001697 10/2013+/- 25 mVThe following illustration shows the analog/digital relation at +/- 25 mV:

Página 50

31001697 10/2013 143Modicon M omentum I/O Base170 AAO 120 0031001697 10/2013170 AAO 120 00 Analog 4 Channel Output Module Base +/- 10 V, 0 - 20 mAChap

Página 51 - 31001697 10/2013 51

170 AAO 120 0014431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AAO 120 00 I/O base

Página 52 - Procedure 2

170 AAO 120 0031001697 10/2013 145LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 53

170 AAO 120 0014631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AAO 120 00 I/O base.General SpecificationsIsol

Página 54 - Inserting Terminal Connectors

170 AAO 120 0031001697 10/2013 147EMCPhysical DimensionsNOTE: The 24 VDC actuator power supply is protected in the same way as the analog outputs (dif

Página 55 - Removing a Terminal Connector

170 AAO 120 0014831001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 56 - Attaching a Busbar

170 AAO 120 0031001697 10/2013 149Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions. Terminal ConnectorTo connect

Página 57 - 31001697 10/2013 57

31001697 10/2013 15Safety InformationImportant InformationNOTICERead these instructions carefully, and look at the equipment to become familiar with t

Página 58

170 AAO 120 0015031001697 10/2013Fuse RequiredThe 1 A slow-blow fuse shown in the wiring diagram (see page 151) must be wired into the actuator power

Página 59 - Chapter 4

170 AAO 120 0031001697 10/2013 151Wiring DiagramsOverviewThis section contains a diagram to assist you in wiring the following types of devices:  out

Página 60 - Dimensions and Mounting

170 AAO 120 0015231001697 10/2013I/O MappingOverviewThe 170 AAO 120 00 TSX Momentum I/O base supports 4 analog outputs. This section contains informat

Página 61

170 AAO 120 0031001697 10/2013 153Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be comm

Página 62

170 AAO 120 0015431001697 10/2013Parameter CodesThe value entered in this word defines the behaviour of the I/O module in case of loss of communicatio

Página 63

170 AAO 120 0031001697 10/2013 155Analog OutputsOverviewThis section describes how to interpret the value of the analog output channels.KeyThis sectio

Página 64

170 AAO 120 0015631001697 10/2013Output RangesOverviewThis section contains illustrations explaining the analog/digital relation for the voltage and c

Página 65 - Mounting TSX Momentum Devices

31001697 10/2013 157Modicon M omentum I/O Base170 AAO 921 0031001697 10/2013170 AAO 921 00 Analog 4 Channel Output Module Base +/- 10 V, 4 ... 20 mACh

Página 66 - Mounting on a Wall

170 AAO 921 0015831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AAO 921 00 I/O base

Página 67 - Chapter 5

170 AAO 921 0031001697 10/2013 159LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 68 - Voltage Types

16 31001697 10/2013PLEASE NOTEElectrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibil

Página 69 - Power and Grounding

170 AAO 921 0016031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AAO 921 00 I/O base.General SpecificationsIsol

Página 70 - Selecting Power Supplies

170 AAO 921 0031001697 10/2013 161EMCPhysical DimensionsNOTE: The 24 VDC actuator power supply is protected in the same way as the analog outputs (dif

Página 71 - 31001697 10/2013 71

170 AAO 921 0016231001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 72 - Potential Isolation

170 AAO 921 0031001697 10/2013 163Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions. Terminal ConnectorTo connect

Página 73 - 31001697 10/2013 73

170 AAO 921 0016431001697 10/2013Fuse RequiredThe 1 A slow-blow fuse shown in the wiring diagram (see page 165) must be wired into the actuator power

Página 74 - Example 2

170 AAO 921 0031001697 10/2013 165Wiring DiagramsOverviewThis section contains a diagram to assist you in wiring the following types of devices:  out

Página 75 - 31001697 10/2013 75

170 AAO 921 0016631001697 10/2013I/O MappingOverviewThe 170 AAO 921 00 TSX Momentum I/O base supports four analog output channels. This section contai

Página 76 - Grounding Momentum Devices

170 AAO 921 0031001697 10/2013 167Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be comm

Página 77 - Lines (see page 79)

170 AAO 921 0016831001697 10/2013Parameter CodesThe value entered in this word defines the behaviour of the I/O module in case of loss of communicatio

Página 78 - Illustration

170 AAO 921 0031001697 10/2013 169Analog OutputsOverviewThis section describes how to interpret the value of the analog output channels.KeyThis sectio

Página 79 - Grounding Analog I/O Lines

31001697 10/2013 17About the BookAt a GlanceDocument ScopeThis manual contains complete information about the Momentum I/O bases. It contains only pas

Página 80

170 AAO 921 0017031001697 10/2013Output RangesOverviewThis section contains illustrations explaining the analog/digital relation for the voltage and c

Página 81 - I/O Base Descriptions

31001697 10/2013 171Modicon M omentum I/O Base170 ADI 34 0 0031001697 10/2013170 ADI 340 00 24 VDC - 16 Pt. D iscrete Input Modu le BaseChapter 11170

Página 82

170 ADI 340 0017231001697 10/2013Front Panel ComponentsOverviewThis section contains a photograph of the front panel of the 170 ADI 340 00 I/O base an

Página 83 - Chapter 6

170 ADI 340 0031001697 10/2013 173LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 84

170 ADI 340 0017431001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADI 340 00 I/O base.General SpecificationsIsol

Página 85

170 ADI 340 0031001697 10/2013 175Physical DimensionsDiscrete InputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5 i

Página 86

170 ADI 340 0017631001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 87

170 ADI 340 0031001697 10/2013 177Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. This section contains wiring guidelines

Página 88 - 170 AAI 030 00

170 ADI 340 0017831001697 10/2013A busbar may be attached to this I/O base to provide a fourth row for protective earth (PE).Row Terminal Function1 1.

Página 89

170 ADI 340 0031001697 10/2013 179Wiring DiagramsOverviewThis section contains an illustration to assist you in wiring the following types of devices:

Página 90

18 31001697 10/2013Related DocumentsYou can download these technical publications and other technical information from our website at www.schneider-el

Página 91

170 ADI 340 0018031001697 10/20133- and 4-Wire DevicesThe diagram below shows an example of wiring for 3- and 4-wire devices:A 1-row busbar is used to

Página 92 - Wiring Illustrations

170 ADI 340 0031001697 10/2013 181I/O MappingOverviewThe 170 ADI 340 00 TSX Momentum I/O base supports 16 discrete inputs. This section contains infor

Página 93

170 ADI 340 0018231001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 94

170 ADI 340 0031001697 10/2013 183The figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When the I/O is

Página 95 - 31001697 10/2013 95

170 ADI 340 0018431001697 10/2013

Página 96

31001697 10/2013 185Modicon M omentum I/O Base170 ADI 35 0 0031001697 10/2013170 ADI 350 00 24 VDC - 32 Pt. D iscrete Input Modu le BaseChapter 12170

Página 97

170 ADI 350 0018631001697 10/2013Front Panel ComponentsOverviewThis section contains a photograph of the front panel of the 170 ADI 350 00 I/O base an

Página 98

170 ADI 350 0031001697 10/2013 187LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 99 - +/- 20 mA

170 ADI 350 0018831001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADI 350 00 I/O base.General SpecificationsIsol

Página 100 - 4 ... 20 mA

170 ADI 350 0031001697 10/2013 189Physical DimensionsDiscrete InputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5 i

Página 101 - Chapter 7

31001697 10/2013 19Modicon M omentum I/O BaseUsing Mo mentum I/O Bases31001697 10/2013Using Mo mentum I/O BasesPart IUsing Momentum I/O BasesOvervie

Página 102 - Front Panel Components

170 ADI 350 0019031001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 103 - LED Descriptions

170 ADI 350 0031001697 10/2013 191Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions.Terminal ConnectorTo connect

Página 104 - Specifications

170 ADI 350 0019231001697 10/2013The following table shows mapping terminal blocks and optional busbars.Row Terminal Function1 1...16 Inputs for group

Página 105 -  5 V in range of +/- 5 V

170 ADI 350 0031001697 10/2013 193Wiring DiagramsOverviewThis section contains a diagram to assist you in wiring the following types of devices:  2-w

Página 106 - Internal Pin Connections

170 ADI 350 0019431001697 10/20133-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following diag

Página 107 - Field Wiring Guidelines

170 ADI 350 0031001697 10/2013 195I/O MappingOverviewThe 170 ADI 350 00 TSX Momentum I/O base supports 32 discrete inputs. This section contains infor

Página 108 - 170 AAI 140 00

170 ADI 350 0019631001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 109 - Wiring Diagrams

170 ADI 350 0031001697 10/2013 197The figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When the I/O is

Página 110 - I/O Mapping

170 ADI 350 0019831001697 10/2013

Página 111 - Analog Channel Parameters

31001697 10/2013 199Modicon M omentum I/O Base170 ADI 54 0 5031001697 10/2013170 ADI 54 0 50 120 VAC - 16 Po int Discrete Inpu t Module Bas eChapter 1

Página 112 - 31001697 10/2013

2 31001697 10/2013 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of

Página 113 - Analog Inputs

Using Momentum I/O Bases2031001697 10/2013

Página 114

170 ADI 540 5020031001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADI 540 50 I/O base

Página 115 - Input Measuring Ranges

170 ADI 540 5031001697 10/2013 201LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 116

170 ADI 540 5020231001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADI 540 50 I/O base.General SpecificationsIsol

Página 117 - Chapter 8

170 ADI 540 5031001697 10/2013 203Physical DimensionsDiscrete InputsWidth 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Length 141.5 mm (5.5 i

Página 118

170 ADI 540 5020431001697 10/2013Derating CurveThe diagram below depicts the derating curve for this I/O base.

Página 119

170 ADI 540 5031001697 10/2013 205Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 120

170 ADI 540 5020631001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. This section contains wiring guidelines a

Página 121 - Analog Inputs mV Range

170 ADI 540 5031001697 10/2013 207Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices:  2-wi

Página 122 - Errors for Pt100/Pt1000

170 ADI 540 5020831001697 10/20133-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following diag

Página 123 - 31001697 10/2013 123

170 ADI 540 5031001697 10/2013 209I/O MappingOverviewThe 170 ADI 540 50 TSX Momentum I/O base supports 16 discrete inputs. This section contains infor

Página 124

31001697 10/2013 21Modicon M omentum I/O BaseIntroducing the Momentum I/O Bases31001697 10/2013Introducing the TSX Momentum I/O BasesChapter 1Introduc

Página 125 - 31001697 10/2013 125

170 ADI 540 5021031001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC compliant adapter. When the I/O is

Página 126

170 ADI 540 5031001697 10/2013 211The figure below shows how data is mapped on the I/O base with a 984 ladder logic compliant adapter. When the I/O is

Página 127 - 31001697 10/2013 127

170 ADI 540 5021231001697 10/2013

Página 128

31001697 10/2013 213Modicon M omentum I/O Base170 ADI 74 0 5031001697 10/2013170 ADI 74 0 50 230 VAC - 16 Po int Discrete Inpu t Module Bas eChapter 1

Página 129

170 ADI 740 5021431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADI 740 50 I/O base

Página 130

170 ADI 740 5031001697 10/2013 215LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 131 - 170 AAI 520 40

170 ADI 740 5021631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADI 740 50 I/O base.General SpecificationsIsol

Página 132

170 ADI 740 5031001697 10/2013 217Physical DimensionsDiscrete InputsWidth 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Length 141.5 mm (5.5 i

Página 133

170 ADI 740 5021831001697 10/2013Derating CurveThe diagram below depicts the derating curve for this I/O base.

Página 134

170 ADI 740 5031001697 10/2013 219Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 135 - 31001697 10/2013 135

Introducing the Momentum I/O Bases2231001697 10/2013Basic Features of I/O BasesOverviewThis section provides a drawing of a typical I/O base and descr

Página 136 - RTD Parameter Codes

170 ADI 740 5022031001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. This section contains wiring guidelines a

Página 137 - 31001697 10/2013 137

170 ADI 740 5031001697 10/2013 221Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices:  2-wi

Página 138 - Low Voltage Parameter Codes

170 ADI 740 5022231001697 10/20133-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following diag

Página 139

170 ADI 740 5031001697 10/2013 223I/O MappingOverviewThe 170 ADI 740 50 TSX Momentum I/O base supports 16 discrete inputs. This section contains infor

Página 140 - Broken Wire Indication

170 ADI 740 5022431001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 141

170 ADI 740 5031001697 10/2013 225The figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When the I/O is

Página 142 - +/- 25 mV

170 ADI 740 5022631001697 10/2013

Página 143 - Chapter 9

31001697 10/2013 227Modicon M omentum I/O Base170 ADM 350 1031001697 10/2013170 ADM 350 10 24 VDC - 16 Pt. In / 16 Pt. Out Module BaseChapter 15170 AD

Página 144

170 ADM 350 1022831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADI 350 10 I/O base

Página 145

170 ADM 350 1031001697 10/2013 229LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 146

Introducing the Momentum I/O Bases31001697 10/2013 23Ground ContactThis contact provides an earth ground connection to any adapter mounted on the base

Página 147

170 ADM 350 1023031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 350 10 I/O base.General SpecificationsIsol

Página 148

170 ADM 350 1031001697 10/2013 231Physical DimensionsDiscrete InputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5 i

Página 149

170 ADM 350 1023231001697 10/2013Discrete OutputsNOTE: Discrete 24 VDC outputs incorporate thermal shutdown and overload protection. The output curren

Página 150

170 ADM 350 1031001697 10/2013 233Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 151

170 ADM 350 1023431001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 152

170 ADM 350 1031001697 10/2013 235The following table shows mapping terminal blocks and optional busbars.Protective Circuit May Be RequiredWhen contac

Página 153

170 ADM 350 1023631001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 154

170 ADM 350 1031001697 10/2013 237Sensor Activated by OutputThe wiring diagram below shows an example of a sensor activated by an output. The diagram

Página 155 - Analog Outputs

170 ADM 350 1023831001697 10/2013Four-Wire Sensor with a Two-Wire ActuatorThe diagram below shows a four-wire sensor with a two-wire actuator. The pro

Página 156 - Output Ranges

170 ADM 350 1031001697 10/2013 239Broken Wire DetectionThe diagram below shows a three-wire actuator with an optional wiring scheme for broken wire de

Página 157 - Chapter 10

Introducing the Momentum I/O Bases2431001697 10/2013Types of I/O BasesOverviewThis section provides part numbers and descriptions for the TSX Momentum

Página 158

170 ADM 350 1024031001697 10/2013Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 159

170 ADM 350 1031001697 10/2013 241I/O MappingOverviewThe 170 ADM 350 10 TSX Momentum I/O base supports 16 discrete inputs and 16 discrete outputs. Thi

Página 160

170 ADM 350 1024231001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 161

170 ADM 350 1031001697 10/2013 243The figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When the I/O is

Página 162

170 ADM 350 1024431001697 10/2013

Página 163

31001697 10/2013 245Modicon M omentum I/O Base170 ADM 350 1131001697 10/2013170 ADM 350 11 24 VDC - 16 Pt. In / 16 Pt. Out Module BaseChapter 16170 AD

Página 164

170 ADM 350 1124631001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADI 350 11 I/O base

Página 165

170 ADM 350 1131001697 10/2013 247LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 166

170 ADM 350 1124831001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 350 11 I/O base.General SpecificationsIsol

Página 167

170 ADM 350 1131001697 10/2013 249Physical DimensionsDiscrete InputsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length

Página 168

Introducing the Momentum I/O Bases31001697 10/2013 25DiscreteThe following discrete I/O bases are available.NOTE: The 170 ADM 690 50 has been replaced

Página 169

170 ADM 350 1125031001697 10/2013NOTE: Discrete 24 VDC outputs incorporate thermal shutdown and overload protection. The output current of a shortened

Página 170

170 ADM 350 1131001697 10/2013 251Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 171 - Chapter 11

170 ADM 350 1125231001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 172

170 ADM 350 1131001697 10/2013 253The following table shows mapping terminal blocks and optional busbars.Protective Circuit May Be RequiredWhen contac

Página 173

170 ADM 350 1125431001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 174

170 ADM 350 1131001697 10/2013 255Sensor Activated by OutputThe wiring diagram below shows an example of a sensor activated by an output. The diagram

Página 175 - Discrete Inputs

170 ADM 350 1125631001697 10/2013Four-Wire Sensor with a Two-Wire ActuatorThe diagram below shows a four-wire sensor with a two-wire actuator. The pro

Página 176

170 ADM 350 1131001697 10/2013 257Broken Wire DetectionThe diagram below shows a three-wire actuator with an optional wiring scheme for broken wire de

Página 177

170 ADM 350 1125831001697 10/2013Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 178

170 ADM 350 1131001697 10/2013 259I/O MappingOverviewThe 170 ADM 350 11 TSX Momentum I/O base supports 16 discrete inputs and 16 discrete outputs. Thi

Página 179

Introducing the Momentum I/O Bases2631001697 10/2013SpecialsThe following specialty I/O bases are available.Part Number Points Type Details170 AEC 920

Página 180 - 170 ADI 340 00

170 ADM 350 1126031001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 181

170 ADM 350 1131001697 10/2013 261The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 182 - Data Mapping

170 ADM 350 1126231001697 10/2013

Página 183 - 1 inputs

31001697 10/2013 263Modicon M omentum I/O Base170 ADM 350 1531001697 10/2013170 ADM 350 15 24 VDC - 16 Pt. In / 16 Pt. Out Module BaseChapter 17170 AD

Página 184

170 ADM 350 1526431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADI 350 15 I/O base

Página 185 - Chapter 12

170 ADM 350 1531001697 10/2013 265LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe r

Página 186

170 ADM 350 1526631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 350 15 I/O base.NOTE: In order for the 170

Página 187

170 ADM 350 1531001697 10/2013 267EMCPhysical DimensionsDiscrete InputsImmunity IEC 1131-2Surge on auxiliary power supply 500VEmissions EN 50081-2Agen

Página 188

170 ADM 350 1526831001697 10/2013Discrete OutputsNOTE: Discrete 24 VDC outputs incorporate thermal shutdown and overload protection. The output curren

Página 189

170 ADM 350 1531001697 10/2013 269Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 190

31001697 10/2013 27Modicon M omentum I/O BaseSelectin g Other Co mponents31001697 10/2013Selectin g Other TS X Momentum ComponentsChapter 2Selecting

Página 191

170 ADM 350 1527031001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 192

170 ADM 350 1531001697 10/2013 271The following table shows mapping terminal blocks and optional busbars.Protective Circuit May Be RequiredWhen contac

Página 193

170 ADM 350 1527231001697 10/2013Wiring DiagramsOverviewThis section provides a diagram to assist you in wiring 2-wire devices.2-Wire DevicesThe diagr

Página 194 - Simplified Schematics

170 ADM 350 1531001697 10/2013 273I/O MappingOverviewThe 170 ADM 350 15 TSX Momentum I/O base supports 16 discrete inputs and 16 discrete outputs. Thi

Página 195

170 ADM 350 1527431001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 196

170 ADM 350 1531001697 10/2013 275The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 197 - 170 ADI 350 00

170 ADM 350 1527631001697 10/2013

Página 198

31001697 10/2013 277Modicon M omentum I/O Base170 ADM 370 1031001697 10/2013170 ADM 370 10 24 VDC - 16 Pt. In / 8 Pt. Out @ 2 Amp. Module BaseChapter

Página 199 - Chapter 13

170 ADM 370 1027831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 370 10 I/O base

Página 200

170 ADM 370 1031001697 10/2013 279LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 201

Selecting Other Components2831001697 10/2013Which Components Should I Use?OverviewThis topic explains the choices you have in assembling a Momentum I/

Página 202

170 ADM 370 1028031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 370 10 I/O base.General SpecificationsIsol

Página 203

170 ADM 370 1031001697 10/2013 281Physical DimensionsDiscrete InputsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length

Página 204 - Derating Curve

170 ADM 370 1028231001697 10/2013Leakage current (output out) < 1 mA @ 24 VDCSurge (inrush) current 2.8 A for 10 s max.On state voltage drop < 0

Página 205

170 ADM 370 1031001697 10/2013 283Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 206

170 ADM 370 1028431001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 207

170 ADM 370 1031001697 10/2013 285The following table shows mapping terminal blocks and optional busbars.Protective Circuit May Be RequiredWhen contac

Página 208

170 ADM 370 1028631001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 209

170 ADM 370 1031001697 10/2013 287Sensor Activated by OutputThe wiring diagram below shows an example of a sensor activated by an output.The diagram s

Página 210

170 ADM 370 1028831001697 10/2013Four-Wire Sensor with a Two-Wire ActuatorThe diagram below shows a four-wire sensor with a two-wire actuator. The pro

Página 211 - 170 ADI 540 50

170 ADM 370 1031001697 10/2013 289Broken Wire DetectionThe diagram below shows a three-wire actuator with an optional wiring scheme for broken wire de

Página 212

Selecting Other Components31001697 10/2013 29Terminal ConnectorsTerminal connectors must be used to connect I/O devices to the I/O base.BusbarsBusbars

Página 213 - Chapter 14

170 ADM 370 1029031001697 10/2013Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 214

170 ADM 370 1031001697 10/2013 291I/O MappingOverviewThe 170 ADM 370 10 TSX Momentum I/O base supports 16 discrete inputs and 8 discrete outputs. This

Página 215

170 ADM 370 1029231001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 216

170 ADM 370 1031001697 10/2013 293The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 217

170 ADM 370 1029431001697 10/2013

Página 218

31001697 10/2013 295Modicon M omentum I/O Base170 ADM 390 1031001697 10/2013170 ADM 390 10 24 VDC - 16 Pt. In / 12 Pt. Out Monitored Module BaseChapte

Página 219

170 ADM 390 1029631001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 390 10 I/O base

Página 220

170 ADM 390 1031001697 10/2013 297LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 221

170 ADM 390 1029831001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 390 10 I/O base.General SpecificationsIsol

Página 222

170 ADM 390 1031001697 10/2013 299EMCPhysical DimensionsDiscrete InputsImmunity IEC 1131-2Surge on auxiliary power supply 500VEmissions EN 50081-2Agen

Página 223

31001697 10/2013 3Table of ContentsSafety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15About the Book. . . . . . . . . . .

Página 224

Selecting Other Components3031001697 10/2013Communication AdaptersOverviewThis topic describes the function of communication adapters, the types avail

Página 225 - 170 ADI 740 50

170 ADM 390 1030031001697 10/2013Discrete OutputsOutput type Solid state switchOutput supply voltage 24 VDCOutput supply voltage range 20 ... 30 VDCOu

Página 226

170 ADM 390 1031001697 10/2013 301Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 227 - Chapter 15

170 ADM 390 1030231001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 228

170 ADM 390 1031001697 10/2013 303The following table shows mapping terminal blocks and optional busbars.Protective Circuit May Be RequiredWhen contac

Página 229

170 ADM 390 1030431001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 230

170 ADM 390 1031001697 10/2013 3053- and 4-Wire DevicesTo connect a 3- or 4-wire sensor, you need a 2-row busbar.

Página 231

170 ADM 390 1030631001697 10/2013Simplified Input SchematicsThe following diagram shows the field-side input circuitry.Simplified Output SchematicsThe

Página 232

170 ADM 390 1031001697 10/2013 307I/O MappingOverviewThe 170 ADM 390 10 TSX Momentum I/O base supports 16 discrete inputs and 12 discrete outputs. Thi

Página 233

170 ADM 390 1030831001697 10/2013Fault Detection for InputsThe following diagram shows how bits are assigned in the second input word:IEC vs. Ladder L

Página 234

170 ADM 390 1031001697 10/2013 309Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 235 - 31001697 10/2013 235

Selecting Other Components31001697 10/2013 31Processor AdaptersOverviewThis topic describes the function of processor adapters, the types available, a

Página 236

170 ADM 390 1031031001697 10/2013The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is mapp

Página 237 - 170 ADM 350 10

31001697 10/2013 311Modicon M omentum I/O Base170 ADM 390 3031001697 10/2013170 ADM 390 30 24 VDC - 10 Pt. In / 8 Pt. Relay Out Module BaseChapter 201

Página 238

170 ADM 390 3031231001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 390 30 I/O base

Página 239

170 ADM 390 3031001697 10/2013 313LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 240 - Simplified Output Schematics

170 ADM 390 3031431001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 390 30 I/O base.General SpecificationsProt

Página 241

170 ADM 390 3031001697 10/2013 315FusesEMCPhysical DimensionsDiscrete InputsInternal noneExternal: operating voltage (L+) 1 A slow-blow (Bussmann GDC-

Página 242

170 ADM 390 3031631001697 10/2013Relay OutputsInput resistance 4 kOhmResponse time 2.2 ms OFF to ON3.3 ms ON to OFFOutput type Relay normally open out

Página 243 - 2 outputs

170 ADM 390 3031001697 10/2013 317Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 244

170 ADM 390 3031831001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 245 - Chapter 16

170 ADM 390 3031001697 10/2013 319The following table shows mapping terminal blocks and optional busbars.Protective Circuit RequiredTo reduce the effe

Página 246

Selecting Other Components3231001697 10/2013For More InformationFor detailed descriptions of all the processor adapters, refer to the TSX Momentum Pro

Página 247

170 ADM 390 3032031001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 3-wire

Página 248

170 ADM 390 3031001697 10/2013 3214-Wire Sensor with a 3-Wire ActuatorThe diagram below shows field wiring for a 4-wire (24 VDC) sensor and a 3-wire (

Página 249 - Discrete Outputs

170 ADM 390 3032231001697 10/2013Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 250

170 ADM 390 3031001697 10/2013 323I/O MappingOverviewThe 170 ADM 390 30 TSX Momentum I/O base supports 10 discrete inputs and 8 discrete outputs. This

Página 251

170 ADM 390 3032431001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 252

170 ADM 390 3031001697 10/2013 325The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 253 - 31001697 10/2013 253

170 ADM 390 3032631001697 10/2013

Página 254

31001697 10/2013 327Modicon M omentum I/O Base170 ADM 390 3131001697 10/2013170 ADM 390 3 1 24 VDC - 10 Pt. In / 8 Pt. Re lay Out Module Ba seChapter

Página 255 - 170 ADM 350 11

170 ADM 390 3132831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 390 31 I/O base

Página 256

170 ADM 390 3131001697 10/2013 329LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 257

Selecting Other Components31001697 10/2013 33Option AdaptersOverviewThis section describes the function of option adapters, the types available, and w

Página 258

170 ADM 390 3133031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 390 31 I/O base.General SpecificationsProt

Página 259

170 ADM 390 3131001697 10/2013 331FusesEMCPhysical DimensionsDiscrete InputsInternal noneExternal: operating voltage (L+) 1 A slow-blow (Bussmann GDC-

Página 260

170 ADM 390 3133231001697 10/2013Relay OutputsInput resistance 4 kOhmResponse time 2.2 ms OFF to ON3.3 ms ON to OFFOutput type Relay normally open out

Página 261

170 ADM 390 3131001697 10/2013 333Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 262

170 ADM 390 3133431001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 263 - Chapter 17

170 ADM 390 3131001697 10/2013 335The following table shows mapping terminal blocks and optional busbars.Protective Circuit RequiredTo reduce the effe

Página 264

170 ADM 390 3133631001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 3-wire

Página 265

170 ADM 390 3131001697 10/2013 3374-Wire Sensor with a 3-Wire ActuatorThe diagram below shows field wiring for a 4-wire (24 VDC) sensor and a 3-wire a

Página 266

170 ADM 390 3133831001697 10/2013Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 267

170 ADM 390 3131001697 10/2013 339I/O MappingOverviewThe 170 ADM 390 31 TSX Momentum I/O base supports 10 discrete inputs and 8 discrete outputs. This

Página 268

Selecting Other Components3431001697 10/2013Terminal ConnectorsOverviewThis section describes: the function of terminal connectors the coding key fe

Página 269

170 ADM 390 3134031001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 270

170 ADM 390 3131001697 10/2013 341The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 271 - 31001697 10/2013 271

170 ADM 390 3134231001697 10/2013

Página 272

31001697 10/2013 343Modicon M omentum I/O Base170 ADM 540 8031001697 10/2013170 ADM 540 80 120 VAC - 6 Pt. In / 3 Pt. Out Discrete MCC Module BaseChap

Página 273

170 ADM 540 8034431001697 10/2013Front Panel ComponentsOverviewThis section contains a photograph of the front panel of the 170 ADM 540 80 I/O base an

Página 274

170 ADM 540 8031001697 10/2013 345LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 275 - 170 ADM 350 15

170 ADM 540 8034631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 540 80 I/O base.General SpecificationsIsol

Página 276

170 ADM 540 8031001697 10/2013 347Physical DimensionsDiscrete InputsDiscrete Outputs .Width 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Leng

Página 277 - Chapter 18

170 ADM 540 8034831001697 10/2013Modbus PortModbus Port TestsOn State Voltage Drop 1.5 VAC max @ 0.5 AOutput (Load) Current 0.5 A / point,1.5 A / modu

Página 278

170 ADM 540 8031001697 10/2013 349Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 279

Selecting Other Components31001697 10/2013 35Ordering InformationTerminal connectors must be ordered separately. They are available in kits of three.

Página 280

170 ADM 540 8035031001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 2 of the base. The outputs are field wired to row 3. Thi

Página 281

170 ADM 540 8031001697 10/2013 351The following table shows mapping terminal blocks and optional busbars.NOTE: Rows 4, 5, 6 may be added by mounting a

Página 282

170 ADM 540 8035231001697 10/2013Module RS-485 TerminationThe illustration below shows how to properly terminate the module’s RS-485 connector. Y-wire

Página 283

170 ADM 540 8031001697 10/2013 353Wiring DiagramsOverviewThis section contains a diagram to assist you in wiring 2-wire field devices. 2-Wire DevicesT

Página 284

170 ADM 540 8035431001697 10/2013I/O MappingOverviewThe 170 ADM 540 80 TSX Momentum I/O base supports 6 discrete inputs and 3 discrete outputs. This s

Página 285 - 31001697 10/2013 285

170 ADM 540 8031001697 10/2013 355Data MappingThe figure below shows how data is mapped.

Página 286

170 ADM 540 8035631001697 10/2013General Modbus Message RulesPurposeThe following rules state what is expected of the user and what the expected respo

Página 287 - Sensor Activated by Output

170 ADM 540 8031001697 10/2013 357Start AddressStart address of 0 = Modbus register 400001. For example: A Modbus start address of 0 is actually Modbu

Página 288 - 170 ADM 370 10

170 ADM 540 8035831001697 10/2013Control mode 4 failed 34 HexControl mode 5 failed 35 HexControl mode 6 failed 36 HexControl mode 7 failed 37 HexContr

Página 289

170 ADM 540 8031001697 10/2013 359Output WordsOutput Words 4x ... 4x + 1516 words of output data are used for 3 120VAC output points and commands for

Página 290

Selecting Other Components3631001697 10/2013BusbarsOverviewThis section describes: The function of busbars Types of busbars How to choose a busbar

Página 291

170 ADM 540 8036031001697 10/2013Module Shut Down DefinitionThe Module shut down behaviour may be set to: hold last value- or - user defined- or -

Página 292

170 ADM 540 8031001697 10/2013 361Output Word 4Output word 4 contains the port configuration parameters (high byte) and the Modbus slave address (low

Página 293

170 ADM 540 8036231001697 10/2013Output Words Control ModesPurposeThis section describes output words 5 ... 16 control modes.Output Words 5 ... 16Outp

Página 294

170 ADM 540 8031001697 10/2013 363Control Mode 2Control Mode 2 - Block WriteControl Mode 3Control Mode 3 - 1 Block Write And 1 Block Read CommandWord

Página 295 - Chapter 19

170 ADM 540 8036431001697 10/2013Control Mode 4Control Mode 4 - 4 Single Write CommandsControl Mode 5Control Mode 5 - 3 Single Writes and 1 Block Read

Página 296

170 ADM 540 8031001697 10/2013 365Control Mode 6Control Mode 6 - 2 Single Writes And 2 Block Read CommandsNOTE: With control mode 6, words 14 and 16 c

Página 297

170 ADM 540 8036631001697 10/2013Control Mode 8Control Mode 8 - 4 Block Read CommandsNOTE: With control mode 8, words 10, 14 and 16 combined length mu

Página 298

170 ADM 540 8031001697 10/2013 367Input WordsPurposeThis section describes input words.Input Words 3x ... 3x + 1516 words of input data are used for 6

Página 299

170 ADM 540 8036831001697 10/2013Input Word 2Input word 2 contains 6 bits of 120 VAC input data and 8 bits for module status.Input Word 1 High Byte (S

Página 300

170 ADM 540 8031001697 10/2013 369Input Words Control ModesPurposeThis section describes input words control modes.Input Words 3 ... 4NOTE: In control

Página 301

Selecting Other Components31001697 10/2013 37SpecificationsBusbars have the following specifications:How to Choose a BusbarSee the internal pin connec

Página 302

170 ADM 540 8037031001697 10/2013Control Mode 1Control Mode 1 - Modbus MessageControl Mode 2 and 4Control Mode 2 and 4 - Write CommandsControl Mode 3

Página 303 - 31001697 10/2013 303

170 ADM 540 8031001697 10/2013 371Control Mode 7Control Mode 7 - 1 Write Command and 3 Block Read CommandsControl Mode 8Control Mode 8 - 4 Block Read

Página 304

170 ADM 540 8037231001697 10/2013

Página 305 - 3- and 4-Wire Devices

31001697 10/2013 373Modicon M omentum I/O Base170 ADM 690 5031001697 10/2013170 ADM 690 50 120 VAC - 10 Pt. In / 8 Pt. Out Module BasesChapter 23170 A

Página 306 - Simplified Input Schematics

170 ADM 690 5037431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 690 50 I/O base

Página 307

170 ADM 690 5031001697 10/2013 375LED IllustrationTheLEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table belo

Página 308

170 ADM 690 5037631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 690 50 I/O base.General SpecificationsIsol

Página 309

170 ADM 690 5031001697 10/2013 377Physical DimensionsDiscrete InputsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length

Página 310 - 170 ADM 390 10

170 ADM 690 5037831001697 10/2013On state voltage drop < 1.5 VAC @ 0.5 AFault sensing One common voltage supply for output 1 .. 4 and output 5 ...

Página 311 - Chapter 20

170 ADM 690 5031001697 10/2013 379Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 312

Selecting Other Components3831001697 10/2013

Página 313

170 ADM 690 5038031001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 2 of the I/O base. Outputs are field wired to row 3. Thi

Página 314

170 ADM 690 5031001697 10/2013 381The following table shows mapping terminal blocks and optional busbars.Row Terminal Function1 FUSE 1,FUSE 2Internal

Página 315

170 ADM 690 5038231001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices:  2-wir

Página 316 - Relay Outputs

170 ADM 690 5031001697 10/2013 3834-Wire Sensor with a 3-Wire ActuatorThe diagram below shows field wiring for a 4-wire sensor and a 3-wire actuator.

Página 317

170 ADM 690 5038431001697 10/2013Simplified Input SchematicsThe following diagram shows the field-side input circuitry.Simplified Output SchematicsThe

Página 318

170 ADM 690 5031001697 10/2013 385I/O MappingOverviewThe 170 ADM 690 50 TSX Momentum I/O base supports 10 discrete inputs and 8 discrete outputs. This

Página 319 - 31001697 10/2013 319

170 ADM 690 5038631001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 320

170 ADM 690 5031001697 10/2013 387The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 321 - 170 ADM 390 30

170 ADM 690 5038831001697 10/2013

Página 322

31001697 10/2013 389Modicon M omentum I/O Base170 ADM 690 5131001697 10/2013170 ADM 690 51 120 VAC - 10 Pt. In / 8 Pt. Out Module BasesChapter 24170 A

Página 323

31001697 10/2013 39Modicon M omentum I/O BaseAssembly31001697 10/2013AssemblyChapter 3AssemblyOverviewThis chapter describes how to assemble and disas

Página 324

170 ADM 690 5139031001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 690 51 I/O base

Página 325

170 ADM 690 5131001697 10/2013 391LED IllustrationTheLEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table belo

Página 326

170 ADM 690 5139231001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 690 51 I/O base.General SpecificationsIsol

Página 327 - Chapter 21

170 ADM 690 5131001697 10/2013 393Physical DimensionsDiscrete InputsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length

Página 328

170 ADM 690 5139431001697 10/2013On state voltage drop < 1.5 VAC @ 0.5 AFault sensing One common voltage supply for output 1 .. 4 and output 5 ...

Página 329

170 ADM 690 5131001697 10/2013 395Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 330

170 ADM 690 5139631001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 2 of the I/O base. Outputs are field wired to row 3. Thi

Página 331

170 ADM 690 5131001697 10/2013 397The following table shows mapping terminal blocks and optional busbars.Row Terminal Function1 FUSE 1,FUSE 2Internal

Página 332

170 ADM 690 5139831001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices:  2-wir

Página 333

170 ADM 690 5131001697 10/2013 3994-Wire Sensor with a 3-Wire ActuatorThe diagram below shows field wiring for a 4-wire sensor and a 3-wire actuator.

Página 334

4 31001697 10/2013Single Power Supply Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . .71Protective Circuits for DC Actuators. . . .

Página 335 - 31001697 10/2013 335

Assembly4031001697 10/2013Assembling an Adapter and an I/O BaseOverviewA processor adapter or communication adapter can be snapped directly onto a Mom

Página 336

170 ADM 690 5140031001697 10/2013Wiring a 170 ADM 690 51 as a 170 ADM 690 50The following diagram shows the field-side input circuitry.Simplified Inpu

Página 337 - 170 ADM 390 31

170 ADM 690 5131001697 10/2013 401Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 338

170 ADM 690 5140231001697 10/2013I/O MappingOverviewThe 170 ADM 690 51 TSX Momentum I/O base supports 10 discrete inputs and 8 discrete outputs. This

Página 339

170 ADM 690 5131001697 10/2013 403Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 340

170 ADM 690 5140431001697 10/2013The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is mapp

Página 341

31001697 10/2013 405Modicon M omentum I/O Base170 ADM 850 1031001697 10/2013170 ADM 850 10 10 to 60 VDC Module BaseChapter 25170 ADM 850 10 10 to 60 V

Página 342

170 ADM 850 1040631001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADM 850 10 Momentum

Página 343 - Chapter 22

170 ADM 850 1031001697 10/2013 407LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 344

170 ADM 850 1040831001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADM 850 10 Momentum I/O base. General Specific

Página 345

170 ADM 850 1031001697 10/2013 409EMCPhysical DimensionsDiscrete InputsImmunity IEC 1131-2Surge on auxiliary power supply, 500VEmissions EN 50081-2 (l

Página 346

Assembly31001697 10/2013 41ProcedureFollow the steps in the table below to assemble an adapter and an I/O base.Step Action1 Choose a clean environment

Página 347

170 ADM 850 1041031001697 10/2013NOTE: Discrete 10-60 VDC inputs require an Input Voltage Reference (row 3 terminal block, terminals 17 and 18). The I

Página 348 - Modbus Port Tests

170 ADM 850 1031001697 10/2013 411Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 349

170 ADM 850 1041231001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 350

170 ADM 850 1031001697 10/2013 413The following table shows mapping terminal blocks and optional busbars.Protective Circuit May Be RequiredWhen contac

Página 351 - 31001697 10/2013 351

170 ADM 850 1041431001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 352 - Module RS-485 Termination

170 ADM 850 1031001697 10/2013 415Sensor Activated by OutputThe wiring diagram below shows an example of a sensor activated by an output. The diagram

Página 353

170 ADM 850 1041631001697 10/2013Four-Wire Sensor with a Two-Wire ActuatorThe diagram below shows a four-wire sensor with a two-wire actuator. The pro

Página 354

170 ADM 850 1031001697 10/2013 417Broken Wire DetectionThe diagram below shows a three-wire actuator with an optional wiring scheme for broken wire de

Página 355

170 ADM 850 1041831001697 10/2013Simplified Input SchematicsThe following diagram shows the field-side input circuitry.Simplified Output SchematicsThe

Página 356 - General Modbus Message Rules

170 ADM 850 1031001697 10/2013 419I/O MappingOverviewThe 170 ADM 850 10 TSX Momentum I/O base supports 16 discrete inputs and 16 discrete outputs. Thi

Página 357 - 31001697 10/2013 357

Assembly4231001697 10/2013Next StepOnce the adapter and I/O base have been assembled, the device can be mounted on a DIN rail or surface-mounted insid

Página 358

170 ADM 850 1042031001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 359 - Output Words

170 ADM 850 1031001697 10/2013 421The figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When the I/O is

Página 360 -  minimum output (OFF)

170 ADM 850 1042231001697 10/2013

Página 361 - Output Word 4

31001697 10/2013 423Modicon M omentum I/O Base170 ADO 340 0031001697 10/2013170 ADO 340 00 24 VDC - 16 Pt. Discrete Output Module BaseChapter 26170 AD

Página 362 - Output Words Control Modes

170 ADO 340 0042431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 340 00 I/O base

Página 363 - Control Mode 3

170 ADO 340 0031001697 10/2013 425LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 364 - Control Mode 5

170 ADO 340 0042631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 340 00 I/O base.General SpecificationsIsol

Página 365 - 31001697 10/2013 365

170 ADO 340 0031001697 10/2013 427Physical DimensionsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5

Página 366 - Control Mode 8

170 ADO 340 0042831001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 367 - Input Words

170 ADO 340 0031001697 10/2013 429Field Wiring GuidelinesOverviewThe outputs are field wired to row 2 of the base. This section contains wiring guidel

Página 368 - Input Word 2

Assembly31001697 10/2013 43Disassembling an Adapter from an I/O BaseOverviewThis section contains safety precautions and a procedure for disassembling

Página 369 - Input Words Control Modes

170 ADO 340 0043031001697 10/2013The following table shows mapping terminal blocks and optional busbars.Protective Circuit RequiredWhen contacted swit

Página 370

170 ADO 340 0031001697 10/2013 431Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wir

Página 371 - Control Mode 7

170 ADO 340 0043231001697 10/20133-Wire ActuatorThe diagram below shows an example of wiring for 3-wire actuator.Simplified SchematicsThe following di

Página 372 - 170 ADM 540 80

170 ADO 340 0031001697 10/2013 433I/O MappingOverviewThe 170 ADO 340 00 TSX Momentum I/O base supports 16 discrete outputs. This section contains info

Página 373 - Chapter 23

170 ADO 340 0043431001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 374

170 ADO 340 0031001697 10/2013 435The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 375

170 ADO 340 0043631001697 10/2013

Página 376

31001697 10/2013 437Modicon M omentum I/O Base170 ADO 350 0031001697 10/2013170 ADO 350 00 24 VDC - 32 Pt. Discrete Output Module BaseChapter 27170 AD

Página 377

170 ADO 350 0043831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 350 00 I/O base

Página 378

170 ADO 350 0031001697 10/2013 439LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 379

Assembly4431001697 10/2013ProcedureFollow the steps in the table below to remove an adapter from an I/O base.Step Action1 Choose a clean environment t

Página 380

170 ADO 350 0044031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 350 00 I/O base.General SpecificationsIsol

Página 381 - 31001697 10/2013 381

170 ADO 350 0031001697 10/2013 441Physical DimensionsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5

Página 382

170 ADO 350 0044231001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 383 - 170 ADM 690 50

170 ADO 350 0031001697 10/2013 443Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions.Terminal ConnectorTo connect

Página 384

170 ADO 350 0044431001697 10/2013The following table shows mapping terminal blocks and optional busbarsProtective Circuit May Be RequiredWhen contacte

Página 385

170 ADO 350 0031001697 10/2013 445Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wir

Página 386

170 ADO 350 0044631001697 10/20133-Wire ActuatorThe diagram below shows an example of wiring for 3-wire actuator.Simplified SchematicsThe following di

Página 387

170 ADO 350 0031001697 10/2013 447I/O MappingOverviewThe 170 ADO 350 00 TSX Momentum I/O base supports 32 discrete outputs. This section contains info

Página 388

170 ADO 350 0044831001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 389 - Chapter 24

170 ADO 350 0031001697 10/2013 449The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 390

Assembly31001697 10/2013 45Assembling a Processor Adapter and an Option AdapterOverviewIf a TSX Momentum option adapter is used, it is mounted between

Página 391

170 ADO 350 0045031001697 10/2013

Página 392

31001697 10/2013 451Modicon M omentum I/O Base170 ADO 530 5031001697 10/2013170 ADO 530 50 120 VAC - 8 Point Discrete Output @ 2A Module BaseChapter 2

Página 393

170 ADO 530 5045231001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 530 50 I/O base

Página 394

170 ADO 530 5031001697 10/2013 453LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 395

170 ADO 530 5045431001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 530 50 I/O base.General SpecificationsIsol

Página 396

170 ADO 530 5031001697 10/2013 455Physical DimensionsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Length 141.5 mm (5.5

Página 397 - 31001697 10/2013 397

170 ADO 530 5045631001697 10/2013Derating CurveThe diagram below shows the ambient temperature in relation to the load current per point in amps.

Página 398

170 ADO 530 5031001697 10/2013 457Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 399 - 170 ADM 690 51

170 ADO 530 5045831001697 10/2013Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions.Terminal ConnectorTo connect f

Página 400

170 ADO 530 5031001697 10/2013 459The following table shows mapping terminal blocks and optional busbars.Row Terminal Function1 Fuse 1, Fuse 2 Output

Página 401

Assembly4631001697 10/2013Next StepFollow the directions in the next section to mount the assembled adapters on the I/O base.3 Push the processor adap

Página 402

170 ADO 530 5046031001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 403

170 ADO 530 5031001697 10/2013 4613-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following dia

Página 404

170 ADO 530 5046231001697 10/2013Output BehaviorThe snubber circuit is there to protect the triac. When the triac is turned on, it is almost a short a

Página 405 - Chapter 25

170 ADO 530 5031001697 10/2013 463I/O MappingOverviewThe 170 ADO 530 50 TSX Momentum I/O base supports 8 discrete outputs. This section contains infor

Página 406

170 ADO 530 5046431001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 407

170 ADO 530 5031001697 10/2013 465The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 408

170 ADO 530 5046631001697 10/2013

Página 409

31001697 10/2013 467Modicon M omentum I/O Base170 ADO 540 5031001697 10/2013170 ADO 540 50 120 VAC - 16 Point Discrete Output Module BaseChapter 29170

Página 410

170 ADO 540 5046831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 540 50 I/O base

Página 411

170 ADO 540 5031001697 10/2013 469LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 412

Assembly31001697 10/2013 47Mounting the Assembled Adapters on the I/O BaseOverviewThis section gives guidelines, safety precautions and a procedure fo

Página 413 - 31001697 10/2013 413

170 ADO 540 5047031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 540 50 I/O base.General SpecificationsIsol

Página 414

170 ADO 540 5031001697 10/2013 471Physical DimensionsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Length 141.5 mm (5.5

Página 415 - Fuse table for F1

170 ADO 540 5047231001697 10/2013Derating CurveThe diagram depicts the derating curve for this I/O base.

Página 416

170 ADO 540 5031001697 10/2013 473Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 417 - Broken Wire Detection

170 ADO 540 5047431001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 2 of the base. This section contains wiring guidelines a

Página 418

170 ADO 540 5031001697 10/2013 475The following table shows mapping terminal blocks and optional busbars.Protective Circuit RequiredWhen contacted swi

Página 419

170 ADO 540 5047631001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 420

170 ADO 540 5031001697 10/2013 4773-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following dia

Página 421 - 170 ADM 850 10

170 ADO 540 5047831001697 10/2013Output BehaviorThe snubber circuit is there to protect the triac. When the triac is turned on, it is almost a short a

Página 422

170 ADO 540 5031001697 10/2013 479I/O MappingOverviewThe 170 ADO 540 50 TSX Momentum I/O base supports 16 discrete outputs. This section contains info

Página 423 - Chapter 26

Assembly4831001697 10/2013ProcedureFollow the steps in the table below to mount the assembly on an I/O baseStep Action1 Make sure that the I/O base is

Página 424

170 ADO 540 5048031001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 425

170 ADO 540 5031001697 10/2013 481The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is map

Página 426

170 ADO 540 5048231001697 10/2013

Página 427

31001697 10/2013 483Modicon M omentum I/O Base170 ADO730 5031001697 10/2013170 ADO 730 50 230 VAC - 8 Point Discrete Output @ 2A Module BaseChapter 30

Página 428

170 ADO730 5048431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 730 50 I/O base

Página 429

170 ADO730 5031001697 10/2013 485LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table belo

Página 430 - Protective Circuit Required

170 ADO730 5048631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 730 50 I/O base.General SpecificationsIsola

Página 431

170 ADO730 5031001697 10/2013 487Physical DimensionsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Length 141.5 mm (5.5 i

Página 432 - 3-Wire Actuator

170 ADO730 5048831001697 10/2013Derating CurveThe diagram below shows the ambient temperature in relation to the load current per point in amps.

Página 433

170 ADO730 5031001697 10/2013 489Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 434

Assembly31001697 10/2013 493 Push the assembled adapters onto the base, gently pressing the locking tabs inward.Snap #1 shown in the illustration belo

Página 435 - 1 outputs

170 ADO730 5049031001697 10/2013Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions. Terminal ConnectorTo connect f

Página 436

170 ADO730 5031001697 10/2013 4913 1 ... 16 Neutral for individual outputs (1N)17 Neutral 120 VAC for module (N)18 Line 120 VAC for module (L1)4 1 ...

Página 437 - Chapter 27

170 ADO730 5049231001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 438

170 ADO730 5031001697 10/2013 4933-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following diag

Página 439

170 ADO730 5049431001697 10/2013Output BehaviorThe snubber circuit is there to protect the triac. When the triac is turned on, it is almost a short an

Página 440

170 ADO730 5031001697 10/2013 495I/O MappingOverviewThe 170 ADO 730 50 TSX Momentum I/O base supports 8 discrete outputs. This section contains inform

Página 441

170 ADO730 5049631001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is m

Página 442

170 ADO730 5031001697 10/2013 497The figure below shows how data is mapped on the I/O base with a Ladder Logic Compliant adapter. When the I/O is mapp

Página 443

170 ADO730 5049831001697 10/2013

Página 444

31001697 10/2013 499Modicon M omentum I/O Base170 ADO 740 5031001697 10/2013170 ADO 740 50 230 VAC - 16 Point Discrete Output Module BaseChapter 31170

Página 445

31001697 10/2013 5I/O Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133Analog Channel Parameters .

Página 446

Assembly5031001697 10/2013Disassembling a Module with an Option AdapterOverviewThe three-tiered assembly is designed to fit together tightly so it can

Página 447

170 ADO 740 5050031001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 740 50 I/O base

Página 448

170 ADO 740 5031001697 10/2013 501LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 449 - 170 ADO 350 00

170 ADO 740 5050231001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 740 50 I/O base.General SpecificationsIsol

Página 450

170 ADO 740 5031001697 10/2013 503Physical DimensionsDiscrete OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 52 mm (2.05 in)Length 141.5 mm (5.5

Página 451 - Chapter 28

170 ADO 740 5050431001697 10/2013Derating CurveThe diagram below shows the ambient temperature in relation to the load current per point in amps.

Página 452

170 ADO 740 5031001697 10/2013 505Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 453

170 ADO 740 5050631001697 10/2013Field Wiring GuidelinesOverviewThe outputs are field wired to row 2 of the base. This section contains wiring guideli

Página 454

170 ADO 740 5031001697 10/2013 507The following table shows mapping terminal blocks and optional busbars.Row Terminal Function1 Fuse 1, Fuse 2 Output

Página 455

170 ADO 740 5050831001697 10/2013Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 2-wire

Página 456

170 ADO 740 5031001697 10/2013 5093-Wire DevicesThe diagram below shows an example of wiring for 3-wire devices:Simplified SchematicsThe following dia

Página 457

Assembly31001697 10/2013 514 Once snaps 1 and 2 have been disengaged, use the screwdriver to release snaps 3 and 4 on the front of the assembly.5 Gent

Página 458

170 ADO 740 5051031001697 10/2013Output BehaviorThe snubber circuit is there to protect the triac. When the triac is turned on, it is almost a short a

Página 459 - 31001697 10/2013 459

170 ADO 740 5031001697 10/2013 511I/O MappingOverviewThe 170 ADO 740 50 TSX Momentum I/O base supports 16 discrete outputs. This section contains info

Página 460

170 ADO 740 5051231001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 461

170 ADO 740 5031001697 10/2013 513The figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When the I/O is

Página 462 - 170 ADO 530 50

170 ADO 740 5051431001697 10/2013

Página 463

31001697 10/2013 515Modicon M omentum I/O Base170 ADO 830 3031001697 10/2013170 ADO 830 30 6 Pt. Relay Out Module BaseChapter 32170 ADO 830 30 6 Pt. R

Página 464

170 ADO 830 3051631001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ADO 830 30 Relay I/

Página 465

170 ADO 830 3031001697 10/2013 517LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 466

170 ADO 830 3051831001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ADO 830 30 I/O base. General SpecificationsIso

Página 467 - Chapter 29

170 ADO 830 3031001697 10/2013 519Physical DimensionsRelay OutputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5 in)

Página 468

Assembly5231001697 10/2013Procedure 2Follow the steps in the table below to remove the option adapter from the M1 processor.Step Action1 Use a screwdr

Página 469

170 ADO 830 3052031001697 10/2013Output leakage current < 100 microampsFault sensing NoneFault reporting NoneError indication NoneResponse time 10

Página 470

170 ADO 830 3031001697 10/2013 521Internal Pin ConnectionsOverview This section contains an illustration of the I/O base.IllustrationThere are no inte

Página 471

170 ADO 830 3052231001697 10/2013Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions.Terminal ConnectorWith respect

Página 472

170 ADO 830 3031001697 10/2013 523The following table shows mapping terminal blocks and optional busbars.Protective Circuit RequiredWhen contacted swi

Página 473

170 ADO 830 3052431001697 10/2013Wiring DiagramsOverviewThis section provides a diagram to assist you in wiring a 2-wire actuator.2-Wire ActuatorThe d

Página 474

170 ADO 830 3031001697 10/2013 525Simplified Output SchematicsThe following diagram shows the relay output circuitry.

Página 475

170 ADO 830 3052631001697 10/2013I/O MappingOverviewThe 170 ADO 830 30 TSX Momentum I/O base supports 6 relay outputs. This section contains informati

Página 476

170 ADO 830 3031001697 10/2013 527Data MappingThe figure below shows how data is mapped on the I/O base with an IEC Compliant adapter. When the I/O is

Página 477

170 ADO 830 3052831001697 10/2013Data MappingThe figure below shows how data is mapped on the I/O base with a 984 Ladder Logic Compliant adapter. When

Página 478 - 170 ADO 540 50

31001697 10/2013 529Modicon M omentum I/O Base170 AMM 090 0031001697 10/2013170 AMM 090 00 Analog 4 Ch. In / 2 Ch. Out Mo dule Base w/ 24 VDC I/O P

Página 479

Assembly31001697 10/2013 53Using Terminal Connector Coding KeysOverviewThis section describes how to use terminal connector coding keys. It also provi

Página 480

170 AMM 090 0053031001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AMM 090 00 I/O base

Página 481

170 AMM 090 0031001697 10/2013 531LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 482

170 AMM 090 0053231001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AMM 090 00 I/O base.General SpecificationsIsol

Página 483 - Chapter 30

170 AMM 090 0031001697 10/2013 533Physical DimensionsAnalog InputsRange Specific DataWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Lengt

Página 484

170 AMM 090 0053431001697 10/2013Analog OutputsDiscrete InputsNumber of channels 2Conversion time 1 ms for all channelsConversion error at 25 deg. C m

Página 485

170 AMM 090 0031001697 10/2013 535Discrete OutputsA 2-point temperature monitoring circuit protects each discrete output against short-circuiting and

Página 486

170 AMM 090 0053631001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 487

170 AMM 090 0031001697 10/2013 537Field Wiring GuidelinesOverviewThe discrete input points are field wired to row 2 of the base. The discrete output p

Página 488

170 AMM 090 0053831001697 10/2013Mapping terminal blocks and busbars is described in the table below.Protective Circuit May Be RequiredWhen contacted

Página 489

170 AMM 090 0031001697 10/2013 539Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices:Discret

Página 490

Assembly5431001697 10/2013Inserting Terminal ConnectorsOverviewThis section contains safety precautions and a diagram illustrating how to insert termi

Página 491 - 31001697 10/2013 491

170 AMM 090 0054031001697 10/2013Discrete OutputsThe diagram below shows an example of wiring for discrete outputs:Analog OutputsThe diagram below sho

Página 492

170 AMM 090 0031001697 10/2013 541Analog InputsThe diagram below shows an example of wiring for analog inputs:

Página 493

170 AMM 090 0054231001697 10/2013I/O MappingOverviewThe 170 AMM 090 00 TSX Momentum I/O base supports 4 analog inputs, 2 analog outputs,4 discrete inp

Página 494 - 170 ADO730 50

170 AMM 090 0031001697 10/2013 543Discrete I/O MappingThe figure below shows how data is mapped with an IEC Compliant adapter.

Página 495

170 AMM 090 0054431001697 10/2013Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be commi

Página 496

170 AMM 090 0031001697 10/2013 545Codes for Analog Input ParametersUse the following codes to set the parameters for each analog input channel:Example

Página 497

170 AMM 090 0054631001697 10/2013Analog OutputsOverviewThis section describes how to interpret the value of the analog output channels.KeyThis section

Página 498

170 AMM 090 0031001697 10/2013 547Analog InputsOverviewThis section describes how to interpret the value of the analog input channels.KeyThis section

Página 499 - Chapter 31

170 AMM 090 0054831001697 10/2013Discrete Inputs and OutputsOverviewThe 170 AMM 090 00 TSX Momentum I/O base supports 4 discrete inputs and 2 discrete

Página 500

170 AMM 090 0031001697 10/2013 549Input Measuring RangesOverviewThis section contains illustrations explaining the analog/digital relation for the var

Página 501

Assembly31001697 10/2013 55Removing a Terminal ConnectorOverviewThis section describes how to remove a terminal connector from a TSX Momentum I/O base

Página 502

170 AMM 090 0055031001697 10/2013Input Range +/- 5 VThe following diagram shows the analog/digital relation for the input measuring range +/- 5 V. The

Página 503

170 AMM 090 0031001697 10/2013 551Input Range +/- 20 mAThe following diagram shows the analog/digital relation for the input measuring range +/- 20 mA

Página 504

170 AMM 090 0055231001697 10/2013Input Range 1 ... 5 VThe following diagram shows the analog/digital relation for the input measuring range 1 ... 5 V.

Página 505

170 AMM 090 0031001697 10/2013 553Input Range 4 ... 20 mAThe following diagram shows the analog/digital relation for the input measuring range 4 ... 2

Página 506

170 AMM 090 0055431001697 10/2013Output Range +/- 10 VThe following diagram shows the analog/digital relation for the output range +/- 10 V. When the

Página 507 - 31001697 10/2013 507

170 AMM 090 0031001697 10/2013 555Error MessagesOverviewError messages are stored in input word 5 (the 3x +4 register). This section explains how to i

Página 508

170 AMM 090 0055631001697 10/2013Broken Wire Detection (Bit 14))Broken wire detection is possible for the 4 ... 20 mA range. In this case, a current s

Página 509

31001697 10/2013 557Modicon M omentum I/O Base170 AMM 090 0131001697 10/2013170 AMM 090 01 Analog 4 Ch. In / 2 Ch. Out Mo dule Base w/ 12 VDC I/O P

Página 510 - 170 ADO 740 50

170 AMM 090 0155831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AMM 090 01 I/O base

Página 511

170 AMM 090 0131001697 10/2013 559LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 512

Assembly5631001697 10/2013Attaching a BusbarOverviewThis section describes how to attach a busbar to an I/O base.GeneralAn optional busbar may be inse

Página 513

170 AMM 090 0156031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AMM 090 01 I/O base.General SpecificationsIsol

Página 514

170 AMM 090 0131001697 10/2013 561Physical DimensionsAnalog InputsRange Specific DataWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Lengt

Página 515 - Chapter 32

170 AMM 090 0156231001697 10/2013Analog OutputsDiscrete InputsNumber of channels 2Conversion time 1 ms for all channelsConversion error at 25 deg. C m

Página 516

170 AMM 090 0131001697 10/2013 563Discrete OutputsA 2-point temperature monitoring circuit protects each discrete output against short-circuiting and

Página 517

170 AMM 090 0156431001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 518

170 AMM 090 0131001697 10/2013 565Field Wiring GuidelinesOverviewThe discrete input points are field wired to row 2 of the base. The discrete output p

Página 519

170 AMM 090 0156631001697 10/2013Mapping terminal blocks and busbars is described in the table below.Protective Circuit May Be RequiredWhen contacted

Página 520

170 AMM 090 0131001697 10/2013 567Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices: Discre

Página 521

170 AMM 090 0156831001697 10/2013Discrete OutputsThe diagram below shows an example of wiring for discrete outputs:Analog OutputsThe diagram below sho

Página 522

170 AMM 090 0131001697 10/2013 569Analog InputsThe diagram below shows an example of wiring for analog inputs:

Página 523

Assembly31001697 10/2013 57Labeling the Components in the AssemblyOverviewA fill-in label is shipped with each I/O base. This label should be attached

Página 524

170 AMM 090 0157031001697 10/2013I/O MappingOverviewThe 170 AMM 090 01 TSX Momentum I/O base supports 4 analog inputs, 2 analog outputs,4 discrete inp

Página 525

170 AMM 090 0131001697 10/2013 571Discrete I/O MappingThe figure below shows how data is mapped with an IEC Compliant adapter.

Página 526

170 AMM 090 0157231001697 10/2013Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be commi

Página 527 - 170 ADO 830 30

170 AMM 090 0131001697 10/2013 573Codes for Analog Input ParametersUse the following codes to set the parameters for each analog input channel:Example

Página 528 - 3 Common

170 AMM 090 0157431001697 10/2013Analog OutputsOverviewThis section describes how to interpret the value of the analog output channels.KeyThis section

Página 529 - Chapter 33

170 AMM 090 0131001697 10/2013 575Analog InputsOverviewThis section describes how to interpret the value of the analog input channels.KeyThis section

Página 530

170 AMM 090 0157631001697 10/2013Discrete Inputs and OutputsOverviewThe 170 AMM 090 01 TSX Momentum I/O base supports 4 discrete inputs and 2 discrete

Página 531

170 AMM 090 0131001697 10/2013 577Input and Output Measuring RangesOverviewThis section contains illustrations explaining the analog/digital relation

Página 532

170 AMM 090 0157831001697 10/2013Input Range +/- 5 VThe following diagram shows the analog/digital relation for the input measuring range +/- 5 V. The

Página 533 - Range Specific Data

170 AMM 090 0131001697 10/2013 579Input Range +/- 20 mAThe following diagram shows the analog/digital relation for the input measuring range +/- 20 mA

Página 534

Assembly5831001697 10/2013

Página 535 - 31001697 10/2013 535

170 AMM 090 0158031001697 10/2013Input Range 1 ... 5 VThe following diagram shows the analog/digital relation for the input measuring range 1 ... 5 V.

Página 536

170 AMM 090 0131001697 10/2013 581Input Range 4 ... 20 mAThe following diagram shows the analog/digital relation for the input measuring range 4... 20

Página 537

170 AMM 090 0158231001697 10/2013Output Range +/- 10 VThe following diagram shows the analog/digital relation for the output range +/- 10 V. When the

Página 538

170 AMM 090 0131001697 10/2013 583Error MessagesOverviewError messages are stored in input word 5 (the 3x +4 register). This section explains how to i

Página 539

170 AMM 090 0158431001697 10/2013Broken Wire Detection (Bit 14))Broken wire detection is possible for the 4 ... 20 mA range. In this case, a current s

Página 540

31001697 10/2013 585Modicon M omentum I/O Base170AMM11030 Module31001697 10/2013170AMM1103 0 Analog 2 Ch. In / 2 Ch. Out Mo dule Base with 16 Discre

Página 541

170AMM11030 Module58631001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170AMM11030 I/O bas

Página 542

170AMM11030 Module31001697 10/2013 587LED IllustrationThe illustration below shows the LEDs.LED DescriptionsThe following table describes the LEDs.LED

Página 543 - Discrete I/O Mapping

170AMM11030 Module58831001697 10/2013SpecificationsOverviewThis section contains specifications for the 170AMM11030 Momentum I/O base.General Specific

Página 544

170AMM11030 Module31001697 10/2013 589Analog InputsThe following table contains specifications for analog inputs.Analog OutputsThe following table con

Página 545 - 31001697 10/2013 545

31001697 10/2013 59Modicon M omentum I/O BaseDimensio ns and Moun ting31001697 10/2013Dimensio ns and Moun ting InstructionsChapter 4Dimensions and Mo

Página 546

170AMM11030 Module59031001697 10/2013Discrete InputsThe following table contains specifications for discrete inputs.Discrete OutputsThe following tabl

Página 547

170AMM11030 Module31001697 10/2013 591Physical DimensionsThe following table outlines physical dimensions for the I/O base.Number of Groups 1Points pe

Página 548 - Discrete Inputs and Outputs

170AMM11030 Module59231001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between t

Página 549

170AMM11030 Module31001697 10/2013 593Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions for wiring the 170AMM1103

Página 550 - Va (for the linear range):

170AMM11030 Module59431001697 10/2013Mapping Terminal Blocks and BusbarsThe following table shows the mapping of terminal blocks and optional busbars.

Página 551 - Input Range +/- 20 mA

170AMM11030 Module31001697 10/2013 595Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices. 

Página 552 - Input Range 1 ... 5 V

170AMM11030 Module59631001697 10/2013Analog I/O DevicesThe diagram below shows field wiring for analog input and analog output devices.Recommended fus

Página 553 - Input Range 4 ... 20 mA

170AMM11030 Module31001697 10/2013 597I/O MapI/O Map Module ConfigurationThe module must be I/O mapped as 8 contiguous input words and 8 contiguous ou

Página 554 - 170 AMM 090 00

170AMM11030 Module59831001697 10/2013Register for OutputsOverview170AMM11030 analog and discrete output channels are configured by entering the approp

Página 555 - Error Messages

170AMM11030 Module31001697 10/2013 599Word 2Discrete Fail State Reaction and Value RegisterThis word combines the discrete reaction in a fail state an

Página 556

6 31001697 10/2013Chapter 12 170 ADI 350 00 24 VDC - 32 Pt. Discrete Input Module Base. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 557 - Chapter 34

Dimensions and Mounting6031001697 10/2013Dimensions of Assembled TSX Momentum DevicesOverviewThis section contains general information about the dimen

Página 558

170AMM11030 Module60031001697 10/2013Word 6Discrete Output RegisterThis word contains a right justified binary eight bit data field.Words 7 ... 8Map t

Página 559

170AMM11030 Module31001697 10/2013 6014x RegistersOverviewThe 4x registers traffic copped to this module are used for output data as follows.RangeOutp

Página 560

170AMM11030 Module60231001697 10/2013Register for InputsOverviewThe input register is arranged as follows.Word 1The status word (word 1) contains info

Página 561

170AMM11030 Module31001697 10/2013 603Word 2Discrete Input RegisterThis word contains a right justified binary 16 bit data field.Words 3 ... 4Analog I

Página 562

170AMM11030 Module60431001697 10/2013Analog MapOverview170AMM11030 analog values are mapped as follows.NOTE: The display is standardized, and, in each

Página 563 - 31001697 10/2013 563

170AMM11030 Module31001697 10/2013 605Discrete I/O Points and IEC Compliant Data MappingOverviewThe 170AMM11030 base returns 16 discrete input bits to

Página 564

170AMM11030 Module60631001697 10/2013Input and Output RangesRanges and Decimal Values Input Measuring Range ±10 VThe voltage value is calculated with

Página 565

170AMM11030 Module31001697 10/2013 607Output Measuring Range ±10 VThe voltage value is calculated with the following formula using the digital measura

Página 566

170AMM11030 Module60831001697 10/2013

Página 567

31001697 10/2013 609Modicon M omentum I/O Base170 ANR 120 9031001697 10/2013170 ANR 120 9 0 Unipolar Analog 6 Ch. In / 4 Ch. Ou t Module Base wit h 2

Página 568

Dimensions and Mounting31001697 10/2013 61Standard Adapter on a Typical BaseOverviewThis section provides dimensions for a standard processor adapter

Página 569

170 ANR 120 9061031001697 10/2013Front Panel ComponentsOverviewThis section contains a photograph of the front panel of the 170 ANR 120 90 I/O base an

Página 570

170 ANR 120 9031001697 10/2013 611LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 571

170 ANR 120 9061231001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ANR 120 90 I/O base.NOTE: In order for the 170

Página 572

170 ANR 120 9031001697 10/2013 613EnvironmentPhysical DimensionsAnalog InputsStorage temperature -40 TO 85 ° COperating temperature 0 TO 60 ° CHumidit

Página 573 - 31001697 10/2013 573

170 ANR 120 9061431001697 10/2013Analog OutputsDiscrete InputsNumber of output channels 4Range 0 to 10VResolution 14 bitsAccuracy, 25 ° C0.4%Linearity

Página 574

170 ANR 120 9031001697 10/2013 615Discrete OutputsNOTE: The output current of a shortened output is limited to a nondestructive value. The short circu

Página 575

170 ANR 120 9061631001697 10/2013Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 576

170 ANR 120 9031001697 10/2013 617Field Wiring GuidelinesOverviewInputs are field wired to row 2 of the I/O base. Outputs are field wired to row 3. Th

Página 577 - 170 AMM 090 01

170 ANR 120 9061831001697 10/2013Mapping Terminal BlocksThe folowing table shows mapping terminal blocks and optional busbars.Row Terminal Connection

Página 578

170 ANR 120 9031001697 10/2013 619Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices:  Disc

Página 579

Dimensions and Mounting6231001697 10/2013Standard Adapter on a Discrete VAC BaseOverviewIf you are using a discrete VAC I/O base such as a 170 ADI 540

Página 580

170 ANR 120 9062031001697 10/2013Analog I/O DevicesThe diagram below shows an example of wiring for Analog I/O devices:Recommended fuses: F3-use a 1A

Página 581

170 ANR 120 9031001697 10/2013 621I/O MappingOverviewThe 170 ANR 120 90 TSX Momentum I/O base supports 6 analog inputs, 4 analog outputs,8 discrete in

Página 582

170 ANR 120 9062231001697 10/2013Analog I/O MAP170 ANR 120 90 analog values are mapped as follows:NOTE: The display is standardized and in each case t

Página 583

170 ANR 120 9031001697 10/2013 623Discrete I/O MAPThe 170 ANR 120 90 base returns eight discrete input bits to the Processor in one 16-bit word (3x).

Página 584

170 ANR 120 9062431001697 10/2013Output WordsOverviewThis section describes how to use the output words to configure the analog and discrete I/O chann

Página 585 - Chapter 35

170 ANR 120 9031001697 10/2013 625The following table tells how bits are assigned: Valid setting for word one are 0001 ... FFFF It is essential for t

Página 586

170 ANR 120 9062631001697 10/2013The following picture shows how the channels are mapped into word 3:Words 4 ... 7Analog Fail State Value RegisterThe

Página 587

170 ANR 120 9031001697 10/2013 627RangeOutput operating rangeOutput Voltage Data is left justified CommentOutput Range 0 ... 10.000V 0 ... 32000 Nomin

Página 588

170 ANR 120 9062831001697 10/2013Inputs WordsOverviewThis section describes how to interpret the value of the input words.Words UsedThe status of the

Página 589

170 ANR 120 9031001697 10/2013 629Word 2Discrete input registerThis word contains a right justified binary eight bit data field.Words 3 ... 8Analog in

Página 590

Dimensions and Mounting31001697 10/2013 63Processor and Option Adapter on a Typical BaseOverviewThis section provides dimensions for a processor adapt

Página 591 - 31001697 10/2013 591

170 ANR 120 9063031001697 10/2013Input and Qutput Measuring RangesOverviewThis section contains illustrations explaining the analog/digital relation f

Página 592

170 ANR 120 9031001697 10/2013 631Output Range 0 -10 VThe following diagram shows the analog/digital relation for the output measuring range 0 -10 V.

Página 593

170 ANR 120 9063231001697 10/2013Error MessagesInterpreting the Error BitsIf an internal error is detected in the module, the module becomes nonoperat

Página 594

31001697 10/2013 633Modicon M omentum I/O Base170 ANR 120 9131001697 10/2013170 ANR 120 91 Bipolar Analog 6 Ch. In / 4 Ch. Out Module Base with 24 VDC

Página 595

170 ANR 120 9163431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ANR 120 91 I/O base

Página 596 - Recommended fuses:

170 ANR 120 9131001697 10/2013 635LED IllustrationThe illustration below shows the LEDs.LED DescriptionsThe following table describes the LEDs.LED Col

Página 597 - I/O Map Module Configuration

170 ANR 120 9163631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ANR 120 91 TSX Momentum I/O base.NOTE: In orde

Página 598 - Register for Outputs

170 ANR 120 9131001697 10/2013 637Analog InputsAnalog OutputsDiscrete InputsNumber of input channels Six single-endedRange ±10VInput impedance >1 m

Página 599 - 31001697 10/2013 599

170 ANR 120 9163831001697 10/2013Discrete OutputsNOTE: The output current of a shortened output is limited to a nondestructive value. The short circui

Página 600 - 170AMM11030 Module

170 ANR 120 9131001697 10/2013 639Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 601 - 4x Registers

Dimensions and Mounting6431001697 10/2013Processor and Option Adapter on a Discrete VAC BaseOverviewThis section provides dimensions for using process

Página 602 - Register for Inputs

170 ANR 120 9164031001697 10/2013Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions for wiring the 170 ANR 120 91

Página 603 - 31001697 10/2013 603

170 ANR 120 9131001697 10/2013 641Mapping Terminal Blocks and BusbarsThe following table shows mapping terminal blocks and optional busbars.Row Termin

Página 604 - Analog Map

170 ANR 120 9164231001697 10/2013Wiring DiagramsOverviewThis section contains diagrams to assist you in wiring the following types of devices:  Discr

Página 605 - Overview

170 ANR 120 9131001697 10/2013 643Analog I/O DevicesThe diagram below shows field wiring for analog input and analog output devices.Recommended fuses:

Página 606 - Input and Output Ranges

170 ANR 120 9164431001697 10/2013I/O MapI/O Map Module ConfigurationThe module must be I/O mapped as 12 contiguous input and output words. The first 7

Página 607 - Output Measuring Range ±10 V

170 ANR 120 9131001697 10/2013 645Register for OutputsOverview170 ANR 120 91 analog and discrete output channels are configured by entering the approp

Página 608

170 ANR 120 9164631001697 10/2013System Info RegisterThis word enables the module’s operation, and specifies if user shutdown values are expected. Va

Página 609 - Chapter 36

170 ANR 120 9131001697 10/2013 647Words 4 ... 7Analog Fail State Value RegisterThe module always expects four words of user defined data, even if the

Página 610

170 ANR 120 9164831001697 10/20134x RegistersOverviewThe 4x registers traffic copped to this module are used for output data as follows.RangeOutput Op

Página 611

170 ANR 120 9131001697 10/2013 649Register for InputsOverviewThe Input Register is arranged as follows.Word 1The status word (word 0) contains informa

Página 612

Dimensions and Mounting31001697 10/2013 65Mounting TSX Momentum DevicesOverviewThis section contains guidelines for installation and drawings which il

Página 613 - Environment

170 ANR 120 9165031001697 10/2013Words 3 ... 8Analog Input Register Words 3 ... 8 map to the analog input register. Each word in this range contains a

Página 614

170 ANR 120 9131001697 10/2013 651Analog MapOverview170 ANR 120 91 analog values are mapped as follows.NOTE: The display is standardized, and, in each

Página 615 - 31001697 10/2013 615

170 ANR 120 9165231001697 10/2013Discrete I/O Points and IEC Compliant Data MappingOverviewThe 170 ANR 120 91 base returns eight discrete input bits t

Página 616

170 ANR 120 9131001697 10/2013 653Input and Output RangesRanges and Decimal Values Input Measuring Range ±10 VThe voltage value is calculated with the

Página 617

170 ANR 120 9165431001697 10/2013Output Measuring Range ±10 VThe voltage value is calculated with the following formula using the digital measurand: V

Página 618 - Mapping Terminal Blocks

170 ANR 120 9131001697 10/2013 655Interpreting the Error BitsOverviewIf an internal error is detected in the module, the module becomes non-operationa

Página 619

170 ANR 120 9165631001697 10/2013

Página 620

31001697 10/2013 657Modicon M omentum I/O Base170 ARM 370 3031001697 10/2013170 ARM 370 30 24 VDC - 10 Pt. In / 8 Pt. Relay Out Module Base (120 VAC P

Página 621

170 ARM 370 3065831001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 ARM 370 30 I/O base

Página 622 - Analog I/O MAP

170 ARM 370 3031001697 10/2013 659LED IllustrationThe LEDs are shown in the illustration below.LED DescriptionsThe LEDs are described in the table bel

Página 623 - 170 ANR 120 90

Dimensions and Mounting6631001697 10/2013ProcedureFollow the steps in the table below to mount a TSX Momentum assembly on a DIN rail.Mounting on a Wal

Página 624

170 ARM 370 3066031001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 ARM 370 30 I/O base.General SpecificationsIsol

Página 625 - 31001697 10/2013 625

170 ARM 370 3031001697 10/2013 661Physical DimensionsDiscrete InputsWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length 141.5 mm (5.5 i

Página 626

170 ARM 370 3066231001697 10/2013Relay OutputsOutput type Relay normally open outputNumber of points 8Number of groups 2Points per group 4Current capa

Página 627 - Output operating range

170 ARM 370 3031001697 10/2013 663Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between term

Página 628 - Inputs Words

170 ARM 370 3066431001697 10/2013Field Wiring GuidelinesOverviewInputs are field wired to row 1 of the base. The outputs are field wired to row 2. Thi

Página 629 - 31001697 10/2013 629

170 ARM 370 3031001697 10/2013 665The following table shows mapping terminal blocks and optional busbars.Protective Circuit RequiredTo reduce the effe

Página 630

170 ARM 370 3066631001697 10/2013Wiring Inputs to Avoid Error MessagesTo avoid I/O error messages, follow these guidelines when wiring. Inputs requir

Página 631 - Output Range 0 -10 V

170 ARM 370 3031001697 10/2013 667Wiring DiagramsOverviewThis section provides diagrams to assist you in wiring the following types of devices: 3-wir

Página 632

170 ARM 370 3066831001697 10/20134-Wire Sensor with a 3-Wire ActuatorThe diagram below shows field wiring for a 4-wire (24 VDC) sensor and a 3-wire (1

Página 633 - Chapter 37

170 ARM 370 3031001697 10/2013 669Simplified Output SchematicsThe following diagram shows the field-side output circuitry.

Página 634

31001697 10/2013 67Modicon M omentum I/O BasePower an d Grounding31001697 10/2013Power an d Grounding G uidelinesChapter 5Power and Grounding Guidelin

Página 635

170 ARM 370 3067031001697 10/2013I/O MappingOverviewThe 170 ARM 370 30 TSX Momentum I/O base supports 10 discrete inputs and 8 relay outputs. This sec

Página 636

170 ARM 370 3031001697 10/2013 671Data MappingThe figure below shows how data is mapped with an IEC Compliant Adapter. When the I/O is mapped as a dis

Página 637

170 ARM 370 3067231001697 10/2013The figure below shows how data is mapped with a Ladder Logic Compliant Adapter. When the I/O is mapped as discrete i

Página 638

31001697 10/2013 673Modicon M omentum I/O BasePower Supply Modul e31001697 10/2013170 CPS 111 00 TIO P ower Suppl y ModuleChapter 39170 CPS 111 00 TI

Página 639

Power Supply Module67431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 CPS 111 00 Pow

Página 640

Power Supply Module31001697 10/2013 675LED IllustrationThis Module has one LED which is shown in the illustration below.LED DescriptionsThe Pwr OK LED

Página 641 - 31001697 10/2013 641

Power Supply Module67631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 CPS 111 00 power supply module.General Sp

Página 642

Power Supply Module31001697 10/2013 677FusesFault InformationPhysical DimensionsEnvironmental ConditionsAC Input VoltageSelectable by jumperInternal (

Página 643

Power Supply Module67831001697 10/2013Power on Surge Current CurveThe following chart shows power on surge current for 120 VAC + 10% or 240 VAC + 10%D

Página 644

Power Supply Module31001697 10/2013 679Output Current ChartThe following chart shows output current (derating) for uninhibited vertical convection.Out

Página 645

Power and Grounding6831001697 10/2013Voltage TypesOverviewIn planning your circuit layout, you must differentiate between operating voltage, input vol

Página 646

Power Supply Module68031001697 10/2013Terminal ConnectorsAvailable TypesPower is supplied to the module through an 8-pole terminal connector. Two type

Página 647 - 170 ANR 120 91

Power Supply Module31001697 10/2013 681Coding IllustrationInstall coding keys in the positions shown in the following illustration:Mounting the Termin

Página 648

Power Supply Module68231001697 10/2013External Operating Voltage ConnectionsOverviewThis section contains a illustration of the external operating vol

Página 649

Power Supply Module31001697 10/2013 683Electrical safetyPower supply modules may not be operated in parallel. Physically separate input cabling from o

Página 650

Power Supply Module68431001697 10/2013

Página 651

31001697 10/2013 685Modicon M omentum I/O Base31001697 10/2013AppendicesOverviewThe appendices contain general information common to the Momentum I/O

Página 652

686 31001697 10/2013

Página 653

31001697 10/2013 687Modicon M omentum I/O BaseSystem Specifications31001697 10/2013System SpecificationsAppendix ASystem SpecificationsOverviewThis ap

Página 654

System Specifications68831001697 10/2013Power Supply SpecificationsOverviewThis section contains power supply specifications for the following types o

Página 655 - Interpreting the Error Bits

System Specifications31001697 10/2013 689Field Device InterfacesOverviewThis section contains specifications for: operating thresholds, input current

Página 656

Power and Grounding31001697 10/2013 69Structuring Your Power Supply SystemOverviewThis section contains guidelines for planning and wiring your power

Página 657 - Chapter 38

System Specifications69031001697 10/2013Environmental SpecificationsOverviewAll Momentum I/O bases share the following environmental specifications.Ge

Página 658

System Specifications31001697 10/2013 691Noise ImmunityThe tables below contain specifications for noise immunity to line-conducted phenomena..Circuit

Página 659

System Specifications69231001697 10/2013

Página 660

31001697 10/2013 693Modicon M omentum I/O BaseInterference Su ppression31001697 10/2013Interference Su ppressionAppendix BInterference SuppressionInte

Página 661

Interference Suppression69431001697 10/2013

Página 662

31001697 10/2013 695Modicon M omentum I/O BaseIEC 1131 Input Types31001697 10/2013IEC 1131 Input TypesAppendix CIEC 1131 Input TypesInput Voltage and

Página 663

IEC 1131 Input Types69631001697 10/2013

Página 664

31001697 10/2013 697Modicon M omentum I/O BaseField Wire Len gth31001697 10/2013Field Wire Len gthAppendix DField Wire LengthCalculating Field Wire Le

Página 665 - 31001697 10/2013 665

Field Wire Length69831001697 10/2013

Página 666 - 170 ARM 370 30

31001697 10/2013 699Modicon M omentum I/O BaseIEC Symbols31001697 10/2013IEC SymbolsAppendix EIEC SymbolsGlossary of IEC SymbolsOverviewThis appendix

Página 667

31001697 10/2013 7Chapter 16 170 ADM 350 11 24 VDC - 16 Pt. In / 16 Pt. Out Module Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 668

Power and Grounding7031001697 10/2013Selecting Power SuppliesOverviewThis section provides guidelines for selecting power supplies.Using Three-Phase B

Página 669

IEC Symbols70031001697 10/2013Change-over breakAnalog sensor (voltage)Analog sensor (current)Thermocouple ElementResistor, general symbolFuseElectroly

Página 670

31001697 10/2013 701Modicon Momentum I/O Bas eIndex31001697 10/2013Index0-9170AAI03000, 83170AAI14000, 101170AAI52040, 117170AAO12000, 143170AAO92100

Página 671

Index70231001697 10/2013Bbusbar170AMM11030, 593busbars, 36CcircuitsI/O bases, 67componentsI/O bases, 27Ddescription170AMM11030, 587dimensionsI/O bases

Página 672

Index31001697 10/2013 703VvoltageI/O bases, 67Wwire length, 697

Página 673 - Chapter 39

31001697 10/2013 704

Página 674

Power and Grounding31001697 10/2013 71Single Power Supply ConfigurationOverviewThis section contains illustrations of a sample circuit layout, potenti

Página 675

Power and Grounding7231001697 10/2013Potential BundlingIn this example, the output voltage is drawn from a separate power supply.Potential IsolationIn

Página 676

Power and Grounding31001697 10/2013 73Protective Circuits for DC ActuatorsOverviewThis section discusses specific cases when inductive loads at output

Página 677 - 31001697 10/2013 677

Power and Grounding7431001697 10/2013Example 1An example of a protective circuit for inductive DC actuators is illustrated below:K1 contact, e.g., fo

Página 678 - DC Output Voltage

Power and Grounding31001697 10/2013 75Protective Circuits for AC ActuatorsOverviewTo reduce noise potentials and for EMC considerations you may need t

Página 679 - Output Current Chart

Power and Grounding7631001697 10/2013Grounding Momentum DevicesOverviewThis section describes how to provide two types of grounding for assembled Mome

Página 680

Power and Grounding31001697 10/2013 77Grounding SchemeThe illustration below illustrates properly grounding modules and tracks.1 grounding clamp, suc

Página 681 - Power Supply Module

Power and Grounding7831001697 10/2013Grounding DIN Rail Terminals and CabinetsOverviewThis section shows how to ground DIN rail terminals and cabinets

Página 682

Power and Grounding31001697 10/2013 79Grounding Analog I/O LinesOverviewAnalog wires must be grounded directly when entering the cabinet. You may use

Página 683

8 31001697 10/2013Chapter 20 170 ADM 390 30 24 VDC - 10 Pt. In / 8 Pt. Relay Out Module Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 684

Power and Grounding8031001697 10/2013

Página 685 - Appendices

31001697 10/2013 81Modicon M omentum I/O BaseI/O Base Descriptions31001697 10/2013I/O Base DescriptionsPart III/O Base DescriptionsPurposeThis part pr

Página 686 - 686 31001697 10/2013

I/O Base Descriptions8231001697 10/201331 170 ADO 740 50 230 VAC - 16 Point Discrete Output Module Base 49932 170 ADO 830 30 6 Pt. Relay Out Module Ba

Página 687 - Appendix A

31001697 10/2013 83Modicon M omentum I/O Base170 AAI 030 0031001697 10/2013170 AAI 030 00 Analog 8 Channel Differential Input Module BaseChapter 6170

Página 688 - Power Supply Specifications

170 AAI 030 008431001697 10/2013Front Panel ComponentsOverviewThis section contains an illustration of the front panel of the 170 AAI 030 00 I/O base

Página 689 - Field Device Interfaces

170 AAI 030 0031001697 10/2013 85LED IllustrationThis I/O base has one LED, the ready indicator shown in the illustration below.LED DescriptionsThe re

Página 690 - Environmental Specifications

170 AAI 030 008631001697 10/2013SpecificationsOverviewThis section contains specifications for the 170 AAI 030 00 I/O base. General SpecificationsIsol

Página 691 - Noise Immunity

170 AAI 030 0031001697 10/2013 87Physical DimensionsAnalog InputsRange Specific DataWidth 125 mm (4.9 in)Depth (with no adapter) 40 mm (1.54 in)Length

Página 692 - System Specifications

170 AAI 030 008831001697 10/2013NOTE: *Not to be confused with Protective Earth. PE is used here as a European notation for full scale, with the follo

Página 693 - Appendix B

170 AAI 030 0031001697 10/2013 89Internal Pin ConnectionsOverview This section contains an illustration showing the internal connections between termi

Página 694 - Interference Suppression

31001697 10/2013 9Chapter 24 170 ADM 690 51 120 VAC - 10 Pt. In / 8 Pt. Out Module Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 695 - Appendix C

170 AAI 030 009031001697 10/2013Field Wiring GuidelinesOverviewThis section contains wiring guidelines and precautions.Required Terminal ConnectorTo c

Página 696 - IEC 1131 Input Types

170 AAI 030 0031001697 10/2013 91Signal ProtectionTo protect the signal from external noise induced in serial or common mode, we recommend the followi

Página 697 - Appendix D

170 AAI 030 009231001697 10/2013Wiring IllustrationsOverviewThis section contains an illustration to assist you in wiring the I/O base.IllustrationThe

Página 698 - Field Wire Length

170 AAI 030 0031001697 10/2013 93I/O MappingOverviewThe 170 AAI 030 00 TSX Momentum I/O base supports 8 analog inputs. This section contains informati

Página 699 - Appendix E

170 AAI 030 009431001697 10/2013Analog Channel ParametersOverviewParameters must be set for all of the analog channels before the module can be commis

Página 700

170 AAI 030 0031001697 10/2013 95Codes for Analog Input ParametersUse the following codes to set the parameters for each analog input channel:NOTE: Th

Página 701 - 31001697 10/2013 701

170 AAI 030 009631001697 10/2013Analog InputsOverviewThis section describes how to interpret the value of the analog input channels.KeyThis section de

Página 702

170 AAI 030 0031001697 10/2013 97Analog Input ValuesMapping of analog input values is shown below.Broken Wire IndicationBroken wire detection is possi

Página 703 - I/O bases, 67

170 AAI 030 009831001697 10/2013Input Measuring RangesOverviewThis section contains illustrations explaining the analog/digital relation for the three

Página 704 - 31001697 10/2013 704

170 AAI 030 0031001697 10/2013 99+/- 5 VThe following illustration shows the analog/digital relation at +/- 5 V:+/- 20 mAThe following illustration sh